A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of three methods for oxidative stress-induced potassium efflux measurement. | LitMetric

Comparison of three methods for oxidative stress-induced potassium efflux measurement.

Biomed Pharmacother

Laboratoire de Chimie Bio-Inorganique, Faculté de Pharmacie de Dijon, 7 boulevard Jeanne d'Arc, 21079 Dijon, France.

Published: August 2007

The aim of the study was to compare the potassium efflux measurements (flame photometry (FP), specific electrode (SE) and atomic absorption photometry (AAP)) using a model of erythrocytes exposed to an oxidative stress in various conditions of osmolarity. Human erythrocytes were incubated in 3 different values of osmolarity and in the presence of 50mM AAPH, potassium efflux was measured by FP, SE and AAP at t=0 and every 30min for 2h. These methods were similar for the measurement of global potassium efflux. However, SE detected important amounts of potassium at the beginning of the experiment or in absence of AAPH in comparison with AAP and FP. It is noteworthy that these different methods of measurements were not altered by the osmolarity. FP and AAP make it possible to study the potassium efflux during oxidative stress while SE should be used only for global measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biopha.2007.05.008DOI Listing

Publication Analysis

Top Keywords

potassium efflux
20
oxidative stress
8
potassium
6
efflux
5
comparison three
4
three methods
4
methods oxidative
4
oxidative stress-induced
4
stress-induced potassium
4
efflux measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!