A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Liquid chromatography tandem mass spectrometry method for simultaneous determination of antidiabetic drugs metformin and glyburide in human plasma. | LitMetric

Liquid chromatography tandem mass spectrometry method for simultaneous determination of antidiabetic drugs metformin and glyburide in human plasma.

J Pharm Biomed Anal

Department of Chemistry, School of Sciences, Gujarat University, Navrangpura, Ahmedabad 380009, India. Electronic address:

Published: September 2007

A simple and rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous quantitation of antidiabetic drugs metformin and glyburide in human plasma using glimepiride as internal standard (IS). After acidic acetonitrile-induced protein precipitation of the plasma samples, metformin, glyburide and IS were chromatographed on reverse phase C18 (50 mm x 4.6 mm i.d., 5 microm) analytical column. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 3.5 min and calibration curves were linear over the concentration range of 20-2500 ng/ml for metformin and 5-500 ng/ml for glyburide. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy and precision, dilution integrity and stability studies. The recoveries obtained for the analytes and IS (>or=69%) were consistent and reproducible. Inter-batch and intra-batch coefficient of variation across four validation runs (LLOQ, LQC, MQC and HQC) was less than 8%. The accuracy determined at these levels was within +/-8% in terms of relative error (RE). The method was applied to a bioequivalence study of 500 mg metformin and 5mg of glyburide tablet after oral administration to 28 healthy human subjects under condition of fasting.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2007.06.003DOI Listing

Publication Analysis

Top Keywords

metformin glyburide
12
mass spectrometry
8
antidiabetic drugs
8
drugs metformin
8
glyburide human
8
human plasma
8
metformin
5
glyburide
5
liquid chromatography
4
chromatography tandem
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!