A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of Bremsstrahlung as a practical alternative to use of a liquid scintillation counter for the assessment of low activities of 90Y. | LitMetric

Background: The use of 90Y for nuclear medicine therapies has steadily increased over the last 10 years. High administered activities are measured in a calibrated re-entrant ionization chamber, while the most sensitive method of assessment of low activities uses a liquid scintillation counter. This method requires the samples to have an acceptably low quench, and therefore heavily coloured samples must undergo chemical processing before assessment. An alternative method has been investigated to measure low activities of 90Y in a sodium iodide well counter by detection of associated Bremsstrahlung.

Methods: Test samples of 90Y with activities 0.5-730 Bq were measured in a well counter and a liquid scintillation counter, with counting times of 4 h per sample. Both counters were investigated for a relationship between count rate and activity.

Results: The efficiency of the well counter was found to be 0.08 count x s(-1) x Bq(-1), for a specified vial and sample volume. This is poor compared with the liquid scintillation counter efficiency of 1.0 count x s (-1) x Bq(-1). The uncertainty in measurement of a sample with unknown activity was calculated for a 4 h count time: +/-8.0% at 730 Bq and +/-45% at 6 Bq for the well counter; and +/-8.0% and +/-8.1%, respectively, for the liquid scintillation counter. These errors are dominated by the initial measurement of activity to determine counting efficiency, using a calibrator with an accuracy of +/-8%. If long counting times of both samples and background radiation are practicable, it has been found that a well counter can successfully be used to assess low activities of 90Y.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0b013e328274207cDOI Listing

Publication Analysis

Top Keywords

liquid scintillation
20
scintillation counter
20
well counter
20
low activities
16
activities 90y
12
counter
10
assessment low
8
counting times
8
activities
6
liquid
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!