AI Article Synopsis

  • The study aimed to evaluate microleakage in bonded vs. non-bonded high-copper amalgam restorations under both thermocycling and regular conditions.
  • 200 extracted human molar teeth were used to assess the effectiveness of different bonding intermediates applied to two types of amalgams, finding that non-bonded amalgams had significantly higher microleakage.
  • Results indicated that while bonding reduced microleakage, thermocycling did not significantly impact the microleakage levels of bonded amalgams, although some differences were noted between specific bonding agents.

Article Abstract

Introduction: To reduce microleakage in high-copper amalgam restorations, bonding of amalgam was introduced.

Aim: This study compared the microleakage of admixed and spherical amalgams when bonded with different bonding intermediates under thermo- and non-thermocycling conditions.

Method And Materials: Class II butt-joint cavities were prepared in 200 extracted human molar teeth, and randomly divided into 5 groups. Calibra, Duo Cement Plus, RelyX ARC and Amalgambond Plus were applied to 4 of these groups. The fifth group was left untreated. The groups were further divided and restored with either Dispersalloy or Oralloy Magicap S. Ten specimens of each group were thermocycled between 5 degrees C and 55 degrees C, placed in basic fuchsin for 8 hours, sectioned and evaluated for dye penetration under 40X magnification. The mean microleakage scores were analysed using the chi-squared test at a confidence level of 95%.

Results: Microleakage of the non-bonded amalgams was significantly higher (p < 0.0001) than for the bonded amalgams (thermocycled and non-thermocycled). The microleakage of the different intermediates bonded to Dispersalloy (thermocycled and non-thermocycled) was not significantly different (p > 0.05). The microleakage of the different intermediates was not significant different except for Duo Cement compared to Calibra (p < 0.0001), RelyX (p < 0.0001) and Amalgambond (p = 0.0433) and Amalgambond compared to Calibra (p = 0.0433) and RelyX (p = 0.0433). The microleakage of the bonded amalgams was not significantly increased by thermocycling (p > 0.05). The microleakage of the two amalgams when bonded with the same resin cements (thermocycled and non-thermocycled) was not significantly different except for Duo Cement (thermocycled) (p = 0.0051) and RelyX (non-thermocycled) (p = 0.0356).

Conclusions: Bonding amalgam restorations to tooth structure in butt-joint cavities will reduce microleakage of both admixed and spherical amalgam restorations. Thermal stress does not affect the bond adversely.

Download full-text PDF

Source

Publication Analysis

Top Keywords

amalgams bonded
12
amalgam restorations
12
duo cement
12
thermocycled non-thermocycled
12
microleakage
10
microleakage amalgams
8
resin cements
8
reduce microleakage
8
bonding amalgam
8
microleakage admixed
8

Similar Publications

A Critical Review on the Factors Affecting the Bond Strength of Direct Restorative Material Alternatives to Amalgam.

Materials (Basel)

October 2024

Department of Conservative Dentistry and Periodontology, LMU University Hospital, LMU Munich, Goethestr. 70, 80336 Munich, Germany.

This article comprehensively reviews the performance of simplified direct restorative materials that have the potential to be an alternative to amalgam. Following an understanding of the material structures and clinical performances, this review provides an analysis of the bonding mechanisms and influential factors on the bond strength. These factors include substrate-related variations, involving primary vs.

View Article and Find Full Text PDF

Herein, the selenium (Se) modified gold nanoparticles (Se-AuNPs) was synthesized using cerium doped carbon dots (Ce-CDs) as a reducing agent and template. As desired, Se-AuNPs displays enhanced peroxidase (POD)-like activity in the presence of Hg. The mechanism for the enhanced activity was attributed to the increased affinity between Se-AuNPs-Hg and the substrate, in which Se and Au elements have a strong binding capacity to Hg, forming Hg-Se bonds and Au-Hg amalgam to generate more ·OH.

View Article and Find Full Text PDF

Effortless Precision: A Case Report on the Stamp Technique for Posterior Teeth.

Cureus

June 2024

Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND.

The stamping technique, a pivotal process, has undergone significant advancements with the integration of composites. Traditionally, direct or indirect restorative cements, e.g.

View Article and Find Full Text PDF

Effect of Polishing and Universal Bonding Application on Mercury Release from Aged Amalgam after Exposure to Bleaching Agents.

Front Dent

April 2024

Department of Operative Dentistry, Dental Materials Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.

Teeth bleaching is an accepted and modern treatment in cosmetic dentistry. Bleaching agents may affect amalgam restorations and increase mercury release; therefore, patients are at increased risk of mercury exposure in the body. The aim of this study was to investigate the effect of polishing and universal bonding application on mercury release from aged amalgams exposed to bleaching.

View Article and Find Full Text PDF

The purpose of this study was to determine the most effective method for bonding composite resin to artificially aged amalgam. A spherical amalgam alloy was triturated and condensed by hand into cylindrical plastic molds (6 mm in diameter and 4 mm in height) to create 90 specimens, which were then aged for 2 weeks in closed plastic containers at 23°C. The amalgam surfaces underwent 1 of 3 surface treatments (n = 30 per treatment): (1) air particle abrasion (APA) with 50-μm aluminum oxide particles applied with a force of 45 psi from a 10-mm distance, followed by rinsing with deionized water for 60 seconds; (2) APA following the same protocol with subsequent application of a metal primer (Alloy Primer); or (3) coating with 30-μm silica (CoJet) at a force of 45 psi from a 10-mm distance until the surface turned black.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!