A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automatic application of ICRP biokinetic models in voxel phantoms for in vivo counting and internal dose assessment. | LitMetric

Automatic application of ICRP biokinetic models in voxel phantoms for in vivo counting and internal dose assessment.

Radiat Prot Dosimetry

Institute of Radiological Protection and Nuclear Safety (IRSN), Laboratory of Internal Dose Assessment, IRSN/DRPH/SDI/LEDI BP 17, F-92262 Fontenay-aux-Roses Cedex, France.

Published: August 2008

As part of the improvement of calibration techniques of in vivo counting, the Laboratory of Internal Dose Assessment of the Institute of Radiological Protection and Nuclear Safety has developed a computer tool, 'OEDIPE', to model internal contamination, to simulate in vivo counting and to calculate internal dose. The first version of this software could model sources located in a single organ. As the distribution of the contamination evolves from the time of intake according to the biokinetics of the radionuclide, a new facility has been added to the software first to allow complex heterogeneous source modelling and then to automatically integrate the distribution of the contamination in the different tissues estimated by biokinetic calculation at any time since the intake. These new developments give the opportunity to study the influence of the biokinetics on the in vivo counting, leading to a better assessment of the calibration factors and the corresponding uncertainties.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncm345DOI Listing

Publication Analysis

Top Keywords

vivo counting
16
internal dose
12
dose assessment
8
distribution contamination
8
time intake
8
automatic application
4
application icrp
4
icrp biokinetic
4
biokinetic models
4
models voxel
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!