By means of finite element analysis, the optimal thickness of fiber framework placed in a fiber-reinforced composite bridge replacing the mandibular first molar was obtained. Test results demonstrated that more than 30% maximum principal stress was reduced by reinforcing with fiber framework in a thickness of up to 0.6 mm for 1.5-mm occlusal clearance. Indeed, maximum principal stress generated in lower embrasure of connectors was reduced from 107 MPa to 70 MPa by maximizing reinforcement effect.

Download full-text PDF

Source
http://dx.doi.org/10.4012/dmj.26.280DOI Listing

Publication Analysis

Top Keywords

finite element
8
element analysis
8
thickness fiber
8
fiber framework
8
maximum principal
8
principal stress
8
optimum design
4
design fixed
4
fixed partial
4
partial dentures
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!