Minimization of needle deflection in robot-assisted percutaneous therapy.

Int J Med Robot

Canadian Surgical Technologies and Advanced Robotics, London, Ontario, Canada.

Published: June 2007

Background: Needle deflection and tissue deformation are two problems encountered during needle insertion into soft, non-homogeneous tissue. They affect the accuracy of needle placement, which in turn affects the effectiveness of needle-based therapies and biopsies.

Methods: In this study, a needle is inserted using a robot with two degrees of freedom. The needle is modelled as a flexible beam with clamped support at one end, and its deflection is estimated using online force/moment measurements at the needle base. To compensate for the needle deflection, the needle is axially rotated through 180 degrees . The needle deflection estimation data is used to find the insertion depths at which needle rotations are to be performed.

Results: A bevelled-tip needle was inserted into animal tissue. The needle deflection at the target was reduced by about 90%. It was observed that minimization of needle deflection reduced tissue deformation. The proposed method reduced needle deflection more than when needle insertion was performed with constant rotation.

Conclusions: Estimating needle tip position using online force/moment measurement improves the accuracy of robot-assisted percutaneous procedures when imaging feedback is not available.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcs.136DOI Listing

Publication Analysis

Top Keywords

needle deflection
28
needle
16
minimization needle
8
deflection
8
robot-assisted percutaneous
8
tissue deformation
8
needle insertion
8
needle inserted
8
online force/moment
8
deflection needle
8

Similar Publications

The examination of the prostate biopsy procedure is essential in the optimization of the diagnostic pathway of such a prevalent affliction as prostate cancer among men worldwide. With the core needle biopsy being the standard of care for the diagnosis of prostate cancer, the ability to obtain quality core samples is directly related to patient treatment and diagnostic reliability. Needle deflection and dynamic tissue deformation are two chief sources of unrepresentative samples outside of human error.

View Article and Find Full Text PDF

Needle Guide Friction Reduction Utilizing Contact Surface Structure.

SM Radiol J

June 2024

Department of Mechanical Engineering, University of Akron, Akron, OH, USA.

Prostate cancer ranks as the second most common cause of cancer-related mortality among males. A template guided core biopsy procedure is an essential component of prostate cancer diagnosis. Various factors influence the quality of the histological sample that is produced from the biopsy, including tissue fragmentation, needle insertion speed, needle deflection, and sheath cutting speed.

View Article and Find Full Text PDF

Needle-free atrial transseptal access: A safe and reproducible alternative for left atrial catheterization.

Heart Rhythm O2

November 2024

Unidad Médica de Alta Especialidad en Pediatría, Centro Médico Nacional de Occidente, Instituto Mexicano del Seguro Social, Guadalajara, México.

Article Synopsis
  • Left atrial catheterization is a common procedure used to treat heart rhythm issues, but traditional methods involving needles can lead to complications; therefore, needle-free techniques are being investigated.
  • This study evaluates the safety and effectiveness of a new needle-free transseptal access (NeFTA) approach in three Mexican electrophysiology centers, using a guidewire and fluoroscopic guidance instead of a needle.
  • The NeFTA method was successful in 96.18% of cases, with very few complications (only 0.55% experienced pericardial effusion), indicating that it is a safe and reliable technique for accessing the left atrium.
View Article and Find Full Text PDF
Article Synopsis
  • * Six different types of cannulae (18, 20, and 22 gauge) were tested to measure deflection at depths of 40 mm and 80 mm, revealing that curved cannulae showed significantly more deflection compared to straight ones.
  • * The findings highlight the importance of cannula shape for interventionalists, suggesting that curved tips provide better maneuverability and should be considered for procedures that require precise placement.
View Article and Find Full Text PDF

Fully Distributed Shape Sensing of a Flexible Surgical Needle Using Optical Frequency Domain Reflectometry for Prostate Interventions.

IEEE Int Conf Robot Autom

May 2024

Department of Computer and Software Engineering, Polytechnique Montréal, Montréal, QC H3T1J4, Canada.

In minimally invasive procedures such as biopsies and prostate cancer brachytherapy, accurate needle placement remains challenging due to limitations in current tracking methods related to interference, reliability, resolution or image contrast. This often leads to frequent needle adjustments and reinsertions. To address these shortcomings, we introduce an optimized needle shape-sensing method using a fully distributed grating-based sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!