Discrepancies exist in the literature regarding contrast between gray and white matter on spin-echo (SE) T1-weighted MR imaging at 3 T. The present study quantitatively assessed differences in gray matter-white matter contrast on both single- and multi-slice SE T1-weighted imaging between 3 and 1.5 T. SE T1-weighted sequences with the same parameters at both 3 and 1.5 T were used. Contrast-to-noise ratio (CNR) between gray and white matter (CNR(GM-WM)) was evaluated for both frontal lobes. To assess the effects of interslice gap, multi-slice images were obtained with both 0 and 25% interslice gap. Single-slice CNR(GM-WM) was higher at 3 T (17.66 +/- 2.68) than at 1.5 T (13.09 +/- 2.35; P < 0.001). No significant difference in CNR(GM-WM) of multi-slice images with 0% gap was noted between 3 and 1.5 T (3T, 8.61 +/- 2.55; 1.5T, 7.43 +/- 1.20; P > 0.05). Multi-slice CNR(GM-WM) with 25% gap was higher at 3T (12.47 +/- 3.31) than at 1.5 T (9.73 +/- 1.37; P < 0.001). CNR(GM-WM) reduction rate of multi-slice images with 0% gap compared with single-slice images was higher at 3T (0.47 +/- 0.13) than at 1.5 T (0.38 +/- 0.09; P = 0.02). CNR(GM-WM) on single-slice SE T1-weighted imaging and CNR(GM-WM) on multi-slice images with 25% interslice gap were better at 3 T than at 1.5 T. The influence of multi-slice imaging on CNR(GM-WM) was significantly larger at 3T than at 1.5 T.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-007-0688-9 | DOI Listing |
Tomography
January 2025
NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.
: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.
View Article and Find Full Text PDFFront Med (Lausanne)
January 2025
Department of Orthopedic, Dianjiang People's Hospital of Chongqing, Chongqing, China.
Lumbar disc herniation (LDH) affects millions globally, with annual healthcare costs exceeding $100 billion in the United States alone, driving increasing interest in minimally invasive radiological interventions as treatment alternatives. This narrative review examines developments in collagenase chemonucleolysis for LDH, integrating a literature analysis with clinical experience. Key advancements include the transition from single-agent to combination therapies, exploration of diverse injection routes, and the progression from C-arm fluoroscopy to multi-slice CT guidance.
View Article and Find Full Text PDFZhonghua Er Ke Za Zhi
February 2025
Pediatric Heart Center, Children's Hospital of Fudan University, National Children's Medical Center, Shanghai, 201102 China.
To analyze the clinical characteristics,diagnosis and treatment of pediatric myocardial infarction (MI) patients with coronary artery lesions (CAL) after Kawasaki disease (KD). Clinical data including baseline characteristics, KD and CAL information, clinical symptoms at MI onset, electrocardiogram (ECG) and imaging findings, MI treatment, and clinical outcomes of 41 MI patients with CAL after KD admitted to the Children's Hospital of Fudan University from January 2017 to August 2024 were analyzed retrospectively. (1) Demographic characteristics: a total of 41 patients were included (36 males and 5 females).
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Stereotactic and Functional Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; Fraunhofer Institute for Laser Technology (ILT), 52074 Aachen, Germany.
Purpose: Directional deep brain stimulation (dDBS) relies on electrodes steering the stimulation field in a specific direction. Post implantation, however, the intended and real orientation of the lead frequently deviates e.g.
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital of Sichuan University, No.37 Guo Xue Alley, Chengdu, Sichuan 610041, China. Electronic address:
Microstructural parameters are essential in tumor research, aiding in the understanding tumor pathogenesis, grading, and therapeutic efficacy. The imaging microstructural parameters using limited spectrally edited diffusion (IMPULSED) model is the most widely used MR cell size imaging technique, demonstrating success in measuring microstructural parameters of solid tumors in vivo. However, its clinical application is limited by the longer scan times required for both pulsed gradient spin-echo (PGSE) and multiple oscillating gradient spin-echo (OGSE) acquisitions across a range of b-values, which can be burdensome for patients and disrupt clinical workflows.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!