A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Immediate/early function with tapered implants supporting maxillary and mandibular posterior fixed partial dentures: preliminary results of a prospective multicenter study. | LitMetric

Statement Of Problem: While immediate loading in the interforaminal area of the mandible is a documented procedure, there are limited scientific data for immediate/early loading in premolar and molar areas where less bone density is often found and functional loading is high.

Purpose: The purpose of this study was to evaluate if there is a difference between immediate and early loading in premolar and molar areas of the mandible and maxilla and compare data to historic data.

Material And Methods: Fifty-one patients received 120 tapered implants in premolar and molar areas of the mandible and maxilla, for a total of 54 short-span (2 to 4 units) fixed partial dentures. Patients with noncontrolled diseases, periodontal pathology, bruxism, and heavy smokers (more than 10 cigarettes a day) were excluded. Patients were divided into 2 groups, with placement of provisional fixed partial prostheses occurring within 24 hours (n=33) or 6 weeks (n=21) after implant surgery. The provisional prostheses had narrow, flat occlusal surfaces to reduce lateral contacts. Surgery was performed with flap elevation, a surgical guide was used, and sites with bone with lower density were underprepared. Implant insertion torque values were between 35 and 45 Ncm. After 6 months, definitive metal-ceramic prostheses were placed. Patients were monitored clinically and radiographically for marginal bone remodeling at baseline, and 3, 6, and 12 months after loading. All patients were followed for 1 year. Data were analyzed with descriptive statistics.

Results: No implant failure occurred. Mean marginal bone resorption (SD) was 1.24 (0.88) mm for the immediate loading group and 1.19 (1.01) mm for the early loading group after 1 year.

Conclusions: The preliminary results demonstrate that if accurate surgical and prosthetic protocols are followed, immediate and early function are predictable and safe approaches even in premolar and molar areas with low bone density.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0022-3913(07)60008-0DOI Listing

Publication Analysis

Top Keywords

premolar molar
16
molar areas
16
fixed partial
12
tapered implants
8
partial dentures
8
loading premolar
8
bone density
8
early loading
8
areas mandible
8
mandible maxilla
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!