A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adduction of solvent molecules by ions isolated within an ion trap mass spectrometer under atmospheric pressure ionisation conditions. | LitMetric

Benzylpyridine and papaverine, an alkyl quinoline, both produce product ions containing an azepinium ring during atmospheric pressure chemical ionisation or electrospray multistage mass spectrometry. By controlling the trapping conditions, an isolated azepinium ion was held within the trap for an extended period of time without excitation. A subsequent analytical scan revealed a mass spectrum containing ions at two mass-to-charge (m/z) ratios, the first at the m/z of the isolated product ion and the second at an m/z ratio corresponding to the adduction of a molecule of solvent. Isolation and resonance excitation of the adduct ion remove the solvent molecule, resulting in recovery of the azepinium ion at the same signal intensity as the adduct ion. Isolating and trapping the ion for a further period allowed the solvent adduct ion to be re-formed. Modulation of the solvent flowing into the source while the ion was trapped allowed variation in the solvent molecule adducted to the trapped ion. The proportion of the ion current due to the adduct ion depends on the nature of the isolated ion, the proton affinity of the solvent and the length of time for which the ion was trapped. Adduct ion formation, deliberately maximised in this study, can occur to a significant extent under standard ion trap operating conditions, reducing the ion current of product ions of interest and, ultimately, the response in tandem mass spectrometric assays.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.3099DOI Listing

Publication Analysis

Top Keywords

adduct ion
20
ion
17
isolated ion
8
ion trap
8
atmospheric pressure
8
product ions
8
azepinium ion
8
solvent molecule
8
ion trapped
8
ion current
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!