Objective: To explore the effect of the number of two-dimensional (2D) images and x-ray projection angles on the resolution of reconstructed three-dimensional (3D) volumes of intracochlear electrode arrays in cadaveric cat temporal bones using Tuned Aperture Computed Tomography (TACT).

Design: Multiple 2D radiographs (basis images (BI)) of implanted cadaveric cat temporal bones were acquired using a range of projection angles, and imported into the TACT workbench. 3D volumes were reconstructed using varying numbers of BIs. Contrast resolution in the image was determined by comparing the contrast ratio (using maximum and minimum grayscale values) in specified anatomic areas of interest.

Results: Systematically increasing the number of BIs used in the reconstruction process resulted in a systematic increase in contrast resolution. Likewise, increasing the range of effective projection angles, as also the number of such angles used in the TACT computation also increased the contrast resolution of the resulting images.

Conclusions: Precise determination of the location of cochlear implant electrodes in situ is critical to understanding the factors influencing efficacy of electrical stimulation of the deaf ear. Renderings generated with the TACT algorithm produce 3D images permitting visualization of implant electrode features and anatomic details with resolution sufficient to accurately localize electrode contacts within scala tympani. The quality of resulting images, evaluated as a function of image contrast, improved with a larger number of BIs in the reconstruction. Wider projection angles also improved image detail in addition to generating thinner slices. Any loss in contrast was compensated for by the number of BIs. TACT can thus be optimized to provide useful data to help characterize the location of intracochlear electrode arrays.

Download full-text PDF

Source
http://dx.doi.org/10.1097/AUD.0b013e31806dc1e3DOI Listing

Publication Analysis

Top Keywords

projection angles
16
electrode arrays
12
cat temporal
12
temporal bones
12
contrast resolution
12
number bis
12
intracochlear electrode
8
cadaveric cat
8
bis reconstruction
8
contrast
6

Similar Publications

Morphometric measurements of the toe serve as a reference for the objective assessment of the presence of a pathological condition and as a guide for the correct trimming of the hooves. Therefore, the anatomical differences between horses and donkeys oblige an autonomous database with reference values for the donkey. The aim of this study was therefore to provide readings of the distal hind limb on radiographs of donkeys.

View Article and Find Full Text PDF

The decision to undertake rhinoplasty maneuvers during cleft lip repair remains controversial. Little data compare long-term outcomes with and without primary rhinoplasty (PR). This study compared nasolabial outcomes in cohorts with unilateral cleft lip (UCL) treated with and without PR at the Children's Hospital of Philadelphia using standardized aesthetic and anthropometric assessments.

View Article and Find Full Text PDF

Taxonomy of high pressure vibration spectra of zincblende semiconductor alloys based on the percolation model.

Sci Rep

January 2025

Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, ul. Grudziądzka 5, 87-100, Toruń, Poland.

Due to their simple structure (two bond species randomly arranged on a cubic lattice), the zincblende ABC semiconductor alloys (zb-SCA) set a benchmark to explore how physical properties are impacted by disorder. A longstanding controversy was whether the lattice dynamics (phonons), governed by the bond force constant, i.e.

View Article and Find Full Text PDF

The Nile Delta, North Africa's leading gas-producing region, was the focus of this study aimed at delineating gas-bearing sandstone reservoirs from the Pleistocene to Pliocene formations using a combination of pre-stack inversion and rock physics analysis. This research employed seismic inversion techniques, including full-angle stack seismic volumes, well logs, and 3-D with rock physics modeling to refine volumes of P-wave velocity (Vp), S-wave velocity (Vs), and density. Traditional seismic attributes, such as far amplitude, proved insufficient for confirming gas presence, highlighting partial angle stacks, integrated the need for advanced methods.

View Article and Find Full Text PDF

Amoebozoa is a group of single-celled organisms that change their shape during locomotion. However, there is a taxon-specific complex of morphological characters inherent in the moving amoebae, known as locomotive forms. Actin is one of the proteins most important for amoeboid movement that, together with actin-binding proteins, construct the architecture of the cytoskeleton in the amoeboid cells.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!