Two common justifications for orienting cervical screws in an angled direction is to increase pull-out strength and to allow use of longer screws. This concept is widely taught and has guided implant design. Fixed versus variable angle systems may offer strength advantages. The purpose of our study is to test the influence of screw orientation and plate design on the maximum screw pull-out load. Variable and fixed angle 4.0 x 15 mm and 4.0 x 13 mm self-tapping screws were used to affix a Medtronic Atlantis cervical plate to polyurethane foam bone samples (density 0.160/cm). This synthetic product is a model of osteoporotic cancellous bone. The fixed angle screws can only be placed at 12 degrees convergent to the midline and 12 degrees in the cephalad/caudal ("12 degrees up and in") direction. Three groups were tested: (1) all fixed angle screws, (2) variable angle, all screws 12 degrees up and in, (3) variable angle, all screws 90 degrees to the plate. Plate constructs were pulled off with an Instron DynaMight 8841 servohydrolic machine measuring for maximum screw pull-out force. There was no difference between group 1, fixed angle (288.4 +/- 37.7 N) (mean +/- SD) and 2, variable angle group (297.7 +/- 41.31 N P< or =0.73). There was a significant increase in maximum pull-out force to failure for the construct with all screws at 90 degrees (415.2+/-17.4 N) compared with all screws 12 degrees "up and in" (297.4 +/- 41.3 N, P< or =0.0016). Group 3 done with 13 mm screws, showed a trend toward better pull-out strength, compared to group 2 w/15 mm screws (345.2 +/- 20.5 vs. 297.4 +/- 41.3, P< or =0.06). In this plate pull-out model, screw orientation influences maximum force to failure. When all 4 screws are 90 degrees to the plate the construct has the greatest ability to resist pullout. Fixed angle designs show no advantage over variable angle. These findings are contrary to current teaching.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BSD.0b013e31802c2a4aDOI Listing

Publication Analysis

Top Keywords

screws degrees
24
variable angle
20
fixed angle
20
angle screws
16
screw pull-out
12
pull-out force
12
screw orientation
12
screws
12
angle
10
cervical plate
8

Similar Publications

Background: Degenerative lumbar diseases (DLDs) often have significant impacts on patients' quality of life, particularly when cage retropulsion (CR) occurs following lumbar interbody fusion (LIF). In this study, we conducted a meta-analysis to assess the risk factors associated with CR after LIF.

Methods: We retrieved literatures analyzing the risk factors associated with CR following LIF from seven databases.

View Article and Find Full Text PDF

Modification mechanism of potato protein by twin-screw extrusion from the perspective of temperature variation.

Food Chem

January 2025

School of Agricultural Engineering and Food Science, Shandong University of Technology, Zibo 255000, Shandong, China. Electronic address:

Potato protein has attracted much attention due to its unique nutritional and structural properties. In this study, the twin-screw extrusion technology was employed to modify potato protein, while the modification mechanism was investigated from the perspective of temperature variation. Results indicated that extruded potato protein (EPP) led to the extremely significantly decreased surface hydrophobicity (1350 to 307-396) and foaming capacity (41.

View Article and Find Full Text PDF

Background: Pediatric femoral neck fractures (PFNF) are rare but associated with a high rate of serious complications such as avascular femoral head necrosis (AVN). Major risk factors and prognostic tools for an AVN are still unclear. As AVN is a devastating complication, this study aims to evaluate the predictors for AVN following a PFNF.

View Article and Find Full Text PDF

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!