Background Context: Spinal instrumentation is accompanied by various problems, including screw malpositioning. One way of preventing this is the employment of intraoperative biplanar fluoroscopy. However, screw malpositioning despite the use of fluoroscopy has been reported, and exposure to radiation is another burden of this method. Therefore, the purpose of this article was to compare the results of instrumentation applications without using scopy versus the harmful effects of radiation exposed during spinal instrumentation.

Purpose: The aim of this article was to review the literature and this is the first prospective clinical study performed on this subject.

Study Design: Patient report.

Patient Sample: One hundred thirty-two patients with spinal instrumentations were included.

Outcome Measures: Radiological investigation with computed tomography (CT) scans was performed 2 days after the procedure.

Methods: Craniosacral posterior spinal instrumentation was performed without using scopy at the Neurosurgery Clinic of Haseki Training and Research Hospital between January 2000 and January 2005. Postoperative CT analyses were performed to evaluate whether the 527 screws used during posterior instrumentation in a total of 132 patients were positioned correctly. In all cases, the screw applications were performed with regard to anatomic landmarks, whereas the distances were determined according to lesion localizations. Screw malpositioning and the functional effects and relations with interactions with neurovascular structures were examined. At the end of the operations, all patients were examined with direct lateral roentgenograms and CT scans for the evaluation of screw positions.

Results: According to their locations, 75 cervical screwing in 24 patients, 32 upper thoracic screwing in 7 patients, 30 midthoracic screwing in 7 patients, 306 thoracolumbar screwing in 54 patients, and 84 sacral screwing in 40 patients were performed by the senior spinal surgeon (KK). Among all posterior spinal instrumentation applications, the cervical region analyses revealed penetration of the medial wall of vertebral foramen with two (0.4%) screws, penetration of the lateral wall with one (0.2%) screw, and protrusion into the vertebral foramen without vascular penetration with one (0.2%) screw, whereas in the upper thoracic region there was penetration into the lateral pedicle wall with one (0.2%) screw and deviation toward the disc space through the superior end plate with two (0.4%) screws. In the midthoracic region, there was penetration into the disc space with two (0.4%) screws in only one case, whereas in the thoracolumbar complex, there was deviation toward the superior end plate with seven (1.4%) screws in four cases, deviation toward the disc space with two (0.4%) screws, medial wall penetration with six (1.2%) screws (two of which caused nerve root irritation in three cases), and penetration of the lateral wall of pedicle with four (0.8%) screws. In the sacral instrumentations, malpositioning occurred with only two (0.4%) screws because of deviation toward the medial wall. In summary, malpositioning occurred with 30 (5.6%) of the total 527 screws; none of the cases had neural or vascular damage. Two (1.5%) cases were revised for malpositioning and distance errors. The mean duration for preparation of screw introduction site and placement of the screw was 3 minutes. Infection occurred in only one (0.75%) case.

Conclusions: Screw application without fluoroscopy is performed with calculation of all essential anatomic details, and because of the reduction of surgery time, the absence of exposure to radiation, and very low infection rates as a consequence of reduced surgery time, it is a method recommendable for surgeons experienced with screw placement. Besides, its malpositioning rates are within acceptable limits. Because screw malpositioning is also found after biplanar fluoroscopy, the prevention of screw malpositioning requires knowing the anatomic landmarks accurately.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2007.04.002DOI Listing

Publication Analysis

Top Keywords

screw malpositioning
20
screwing patients
20
04% screws
20
screw
15
spinal instrumentation
12
medial wall
12
penetration lateral
12
02% screw
12
disc space
12
screws
10

Similar Publications

Introduction Lumbar pyogenic spondylodiscitis is a challenging and rare spinal infection with high morbidity, particularly in patients with comorbidities. While the extreme lateral interbody fusion (XLIF) technique is established in treating degenerative spinal conditions, its efficacy in managing spondylodiscitis is less well-studied. This study aims to evaluate the clinical and radiographic outcomes of the XLIF approach combined with posterior instrumentation in patients with lumbar spondylodiscitis.

View Article and Find Full Text PDF

Purpose Of The Study: The annual number of spinal fusion procedures has been increasing and is well documented worldwide. The O-arm is slowly becoming the standard for transpedicular screw insertion. The accuracy and safety of this method have been confirmed by many studies.

View Article and Find Full Text PDF

The Latarjet procedure is a successful treatment for anterior shoulder instability, with fewer than 5% of patients having redislocations-revision surgery and prior surgery having been shown to be significant risk factors for recurrence. Approximately 90% of athletes return to play after the Latarjet procedure, comparable to arthroscopic Bankart repair. Patients may be physically unable to return to play, which may be due to persistent pain, apprehension, or weakness.

View Article and Find Full Text PDF

Background: There is no consensus in the literature regarding the optimal treatment method for posterior pelvic ring injuries. This study aims to compare the radiologic and clinical outcomes, as well as complications of spinopelvic fixation (SPF) and iliosacral screw fixation (ISF) in patients with posterior pelvic ring injuries.

Methods: This retrospective study analyzed 54 patients (37 females, 17 males; mean age 38.

View Article and Find Full Text PDF

[The best preferable sagittal vertical axis for the ankylosis spondylitis with thoracolumbar kyphosis following one-level pedicle subtraction osteotomy under different cervical range of motion].

Zhonghua Yi Xue Za Zhi

January 2025

Division of Spine Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing210008, China.

To analyze the influence of cervical range of motion on the preferable sagittal vertical axis in ankylosis spondylitis (AS)-related thoracolumbar kyphosis following single-level pedicle subtraction osteotomy (PSO). The clinical data of sixty-five AS patients who underwent single-level PSO from February 2012 to November 2018 in the Drum Tower Hospital of Nanjing University Medical School were retrospectively reviewed. Of the patients, 59 were males and 6 were females with a mean age of (34.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!