A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Morphometry of the proximal tibia to design the tibial component of total knee arthroplasty for the Korean population. | LitMetric

We carried out an anthropometric analysis using three dimensional computer tomographic measurements of the cut surface of the proximal tibia in 200 knees that were obtained from 50 male and 50 female Korean cadavers. We measured the mediolateral (ML), middle anteroposterior (AP), medial and lateral anteroposterior dimensions and the aspect ratio (ML/AP) of the resected proximal tibial surface; we then compared this data with the five conventionally used symmetric total knee components. We found that the ML (73.5+/-5.6 mm) and AP (47.3+/-3.8 mm) average dimensions of our study population were smaller than the dimensions of the symmetric commercially available TKA implants. We found a progressive decrease in the aspect ratio with the increasing anteroposterior dimension of the proximal tibia, as compared to the constant aspect ratio shown by the conventional tibial prostheses. The smaller sized prostheses were found to show mediolateral undersizing and the larger sized prostheses were found to show mediolateral overhang. This study may provide guidelines for designing a suitable tibial component of total knee prostheses for the Korean population, the aspect ratio of which decreases with increasing anteroposterior dimension.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2007.05.004DOI Listing

Publication Analysis

Top Keywords

aspect ratio
16
proximal tibia
12
total knee
12
tibial component
8
component total
8
korean population
8
increasing anteroposterior
8
anteroposterior dimension
8
sized prostheses
8
prostheses mediolateral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!