Objective: The aim of this study was to further evaluate the safety and effectiveness of balloon catheter devices to dilate obstructed sinus ostia/perform sinusotomy.

Methods: Through a prospective, multicenter evaluation, safety was assessed by rate of adverse events, patency was determined by endoscopic examination, and sinus symptoms were determined by the Sino-Nasal Outcome Test (SNOT 20).

Results: At the conclusion of the 24-week analysis, endoscopy determined that the sinusotomy was patent in 80.5% (247 of 307) sinuses and nonpatent in 1.6% (5 of 307), and could not determine ostial patency status in 17.9% (55 of 307). Of the ostia visualized on endoscopy, 98% were patent (247 of 252), while 2% (5 of 252) were considered nonpatent. SNOT 20 scores showed consistent symptomatic improvement over baseline. Revision treatment was required in 3 sinuses (3 of 307 sinuses, 0.98%) in 3 patients (3 of 109 patients, 2.75%).

Conclusion: Balloon catheter technology appears safe and effective in relieving ostial obstruction. Patients were pleased and indicated that they experienced symptomatic improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otohns.2007.02.006DOI Listing

Publication Analysis

Top Keywords

balloon catheter
12
24-week analysis
8
307 sinuses
8
symptomatic improvement
8
safety outcomes
4
outcomes balloon
4
catheter sinusotomy
4
sinusotomy multicenter
4
multicenter 24-week
4
analysis 115
4

Similar Publications

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.

Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.

View Article and Find Full Text PDF

Background: Protruding coronary artery stents can adversely affect transcatheter aortic valve replacement (TAVR) procedure. Current evidence on the topic is limited.

Aims: We aim to study the clinical feasibility and safety of flaring of protruding coronary artery stents before TAVR to reduce interaction with transcatheter heart valves.

View Article and Find Full Text PDF

Retrieval of a Fractured Balloon Catheter Fragment.

J Vasc Interv Radiol

January 2025

Division of Vascular and Interventional Radiology, Department of Radiology, Baylor College of Medicine, Houston, Texas. Electronic address:

View Article and Find Full Text PDF

Background And Objectives: Traditional manual percutaneous coronary intervention (PCI) exposes operators to significant radiation and physical stress. The recently developed Advanced Vascular Intervention Assist Robot (AVIAR) 2.0 system in South Korea aimed to overcome these issues by evaluating its safety and feasibility in a clinical setting.

View Article and Find Full Text PDF

Background: Cryoballoon ablation has been widely performed in patients with paroxysmal atrial fibrillation (AF). In some challenging pulmonary veins (PVs), the procedure requires additional touch-up applications against the residual conduction gaps. It implies that there could exist difficult sites to cover with standard cryoballoon applications (CBAs), resulting in resistant conduction gaps (RCGs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!