A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of mercury in whole blood and urine by inductively coupled plasma mass spectrometry. | LitMetric

The conventional method for the determination of mercury in clinical samples is cold vapor atomic absorption spectrometry. Sample digestion or pretreatment require large sample volume and long sample preparation time. The inductively coupled plasma mass spectrometry (ICP-MS) method developed in this study requires only 100 microL of sample with practically no preparation, except for dilution with diluent. Significant savings in sample volumes, reagents, technician time, and analysis time are realized. Among different types of diluents, the one containing acid, tert-butanol, and potassium dichromate gave the best results to remove the mercury memory effect. The interassay precisions for whole blood and urine were < 5% and < 8%, respectively, and the intra-assay precisions were < 3% and < 7%, respectively. The lower limits of detection were 0.13, 0.17, and 0.26 microg/L for aqueous standard, urine, and whole blood, respectively. The developed ICP-MS method correlated well with the atomic absorption method and can offer an alternative to the atomic absorption method for mercury analysis with less sample volume requirement as well as shorter analysis time.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/31.5.281DOI Listing

Publication Analysis

Top Keywords

atomic absorption
12
determination mercury
8
blood urine
8
inductively coupled
8
coupled plasma
8
plasma mass
8
mass spectrometry
8
sample volume
8
icp-ms method
8
analysis time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!