Continuous-flow single-molecule CE with high detection efficiency.

Electrophoresis

Department of Chemistry, University of Washington, Seattle, WA 98195-1700, USA.

Published: July 2007

This paper describes the use of two-beam line-confocal detection geometry for measuring the total mobility of individual molecules undergoing continuous-flow CE separation. High-sensitivity single-molecule confocal detection is usually performed with a diffraction limited focal spot (approximately 500 nm in diameter), which necessitates the use of nanometer-sized channels to ensure all molecules flow through the detection volume. To allow for the use of larger channels that are a few micrometers in width, we employed cylindrical optics to define a rectangular illumination area that is diffraction-limited (approximately 500 nm) in width, but a few micrometers in length to match the width of the microchannel. We present detailed studies that compare the performance of this line-confocal detection geometry with the more widely used point-confocal geometry. Overall, we found line-confocal detection to provide the highest combination of signal-to-background ratio and spatial detection efficiency when used with micrometer-sized channels. For example, in a 2 microm wide channel we achieved a 94% overall detection efficiency for single Alexa488 dye molecules when a 2 microm x 0.5 microm illumination area was used, but only 34% detection efficiency with a 0.5 microm-diameter detection spot. To carry out continuous-flow CE, we used two-beam fluorescent cross-correlation spectroscopy where the transit time of each molecule is determined by cross-correlating the fluorescence registered by two spatially offset line-confocal detectors. We successfully separated single molecules of FITC, FITC-tagged glutamate, and FITC-tagged glycine.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200600730DOI Listing

Publication Analysis

Top Keywords

detection efficiency
16
line-confocal detection
12
detection
10
detection geometry
8
illumination area
8
continuous-flow single-molecule
4
single-molecule high
4
high detection
4
efficiency
4
efficiency paper
4

Similar Publications

The utilization of dual-working-electrode mode of interdigitated array (IDA) electrodes and other two-electrode systems has revolutionized electrochemical detection by enabling the simultaneous and independent detection of two species, accompanied by the exhibition of unique characteristics. In contrast to conventional dual-potential electrodes, such as the rotating ring disk electrodes (RRDE), IDA electrodes demonstrate analogous yet vastly improved performance, characterized by remarkable collection efficiency and sensitivity. Notably, due to the distinctive microscale structure of IDA electrode, the special "feedback" effect makes IDA a unique signal amplifier.

View Article and Find Full Text PDF

Mold defects pose a significant risk to the preservation of valuable fine art paintings, typically arising from fungal growth in humid environments. This paper presents a novel approach for detecting and categorizing mold defects in fine art paintings. The technique leverages a feature extraction method called Derivative Level Thresholding to pinpoint suspicious regions within an image.

View Article and Find Full Text PDF

Maize quality detection based on MConv-SwinT high-precision model.

PLoS One

January 2025

Engineering Research Center of Hydrogen Energy Equipment& Safety Detection, Universities of Shaanxi Province, Xijing University, Xi'an, China.

The traditional method of corn quality detection relies heavily on the subjective judgment of inspectors and suffers from a high error rate. To address these issues, this study employs the Swin Transformer as an enhanced base model, integrating machine vision and deep learning techniques for corn quality assessment. Initially, images of high-quality, moldy, and broken corn were collected.

View Article and Find Full Text PDF

Background: Multi-cancer early detection (MCED) tests may expand cancer screening. Characterizing diagnostic resolution approaches following positive MCED tests is critical. Two trials employed distinct resolution approaches: a molecular signal to predict tissue of origin (TOO) and an imaging-based diagnostic strategy.

View Article and Find Full Text PDF

Purpose: This study aims to conduct a mini review of published literature concerning the role of exosomes in the field of ophthalmology, with a specific focus on Age-Related Macular Degeneration (AMD).

Methods: In this study, a comprehensive search was conducted using PubMed and Google Scholar to identify relevant publications. Additionally, trials submitted to clinicaltrials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!