Unlabelled: The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/CT and the performance of a software-based approach for reregistration.
Methods: We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight.
Results: The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 +/- 3.8 mm (1.25 +/- 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration.
Conclusion: Misregistration occurs with SPECT/CT systems and influences regional tracer distribution on attenuation-corrected myocardial images. Reregistration of misaligned studies may be a useful tool for correction. The impact of this strategy on the diagnostic and prognostic accuracy of cardiac hybrid imaging needs to be determined.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2967/jnumed.107.040535 | DOI Listing |
Rev Esp Med Nucl Imagen Mol (Engl Ed)
December 2024
Department of Radiology, University of Health Sciences, Prof. Dr. Cemil Tascioglu City Hospital, Istanbul, Turkey.
Aim: This study aimed to investigate the relationship between PET and CT parameters and sarcopenia, adipose tissue, and tumor metabolism in esophageal carcinoma (EC) and its impact on survival in EC.
Method: Our study included 122 EC patients who underwent PET/CT for staging. Muscle and adipose tissue characteristics were evaluated, including lumbar (L3) and cervical (C3) muscle areas, psoas major (PM) and sternocleidomastoid muscle (SCM) parameters, and PET parameters for visceral and subcutaneous adipose tissue (SAT).
Rev Esp Med Nucl Imagen Mol (Engl Ed)
December 2024
Selcuk University Medical Faculty, Department of Nuclear Medicine, Konya, Turkey.
Introduction And Objectives: Tissue attenuation reduces the specificity of the myocardial perfusion imaging single photon emission tomography (SPECT), which leads reduced diagnostic accuracy. The aim of this study is to compare performances of non-attenuation corrected (NAC), computed tomography based-attenuation corrected (AC) and prone images for qualitative and semi-quantitative analysis of myocardial perfusion SPECT in diagnosis of coronary artery disease (CAD).
Materials And Methods: Eightysix patients in whom NAC, AC and prone images were obtained with SPECT at Selcuk University Faculty of Medicine, and whose coronary angiography/CT coronary angiography was completed within 3 months, were retrospectively studied.
Radiol Oncol
December 2024
Demiroglu Bilim University, İstanbul, Turkey.
Biomed Phys Eng Express
December 2024
Department of Physics, Faculty of Science University of Guilan, Rasht, Iran.
Attenuation correction of PET data is commonly conducted through the utilization of a secondary imaging technique to produce attenuation maps. The customary approach to attenuation correction, which entails the employment of CT images, necessitates energy conversion. However, the present study introduces a novel deep learning-based method that obviates the requirement for CT images and energy conversion.
View Article and Find Full Text PDFClin Nucl Med
November 2024
A 46-year-old woman underwent 131 I radiotherapy following thyroidectomy for papillary thyroid carcinoma. Posttherapeutic 131 I scintigraphy was performed 4 days later. Both attenuation-corrected and non-attenuation-corrected 131 I tomography images elucidated an intrauterine device with avid 131 I uptake in her uterus.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!