A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic accuracy of 64-slice CT in the assessment of coronary stents. | LitMetric

Purpose: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis.

Materials And Methods: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml, Iomeron, Bracco) and a bolus chaser (40 ml of saline), the scan was completed in <12 s. All coronary segments with a stent were assessed on 64-CT by two observers in consensus and judged as: patent, with intimal hyperplasia (lumen reduction of <50%), with in-stent restenosis (> or =50%), or with in-stent occlusion (100%). The consensus reading was compared with conventional coronary angiography.

Results: Four patients were excluded because of insufficient image quality. In the remaining 91, we assessed 102 stents (31 RCA; 10 LM; 54 LAD; 7 CX). In 14 (13.7%) stents, in-stent restenosis (n=8) or in-stent occlusion (n=6) was found. Intimal hyperplasia was detected in 11 (10.8%) stents. The sensitivity and negative predictive value of 64-CT for in-stent occlusion were 100% and 100%, respectively, whereas for all stenoses, >50% they were 92.9% and 98.7%, respectively.

Conclusions: We found that 64-CT has a high diagnostic accuracy for the detection of in-stent restenosis in a selected patient population.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11547-007-0159-zDOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
12
accuracy 64-slice
8
64-slice assessment
4
coronary
4
assessment coronary
4
coronary stents
4
stents purpose
4
purpose purpose
4
purpose study
4
study assess
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!