The accuracy of the Leksell GammaPlan, the dose planning system of the Gamma Knife Model-B, was evaluated near tissue inhomogeneities, using the gel dosimetry method. The lack of electronic equilibrium around the small-diameter gamma beams can cause dose calculation errors in the neighborhood of an air-tissue interface. An experiment was designed to investigate the effects of inhomogeneity near the paranosal sinuses cavities. The homogeneous phantom was a spherical glass balloon of 16 cm diameter, filled with MAGIC gel; i.e., the normoxic polymer gel. Two hollow PVC balls of 2 cm radius, filled with N2 gas, represented the air cavities inside the inhomogeneous phantom. For dose calibration purposes, 100 ml gel-containing vials were irradiated at predefined doses, and then scanned in a MR unit. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. Dose distributions are the results of a single shot of irradiation, obtained by collimating all 201 cobalt sources to a known target in the phantom. Both phantoms were irradiated at the same dose level at the same coordinates. Stereotactic frames and fiducial markers were attached to the phantoms prior to MR scanning. The dose distribution predicted by the Gamma Knife planning system was compared with that of the gel dosimetry. As expected, for the homogeneous phantom the isodose diameters measured by the gel dosimetry and the GammaPlan differed by 5% at most. However, with the inhomogeneous phantom, the dose maps in the axial, coronal and sagittal planes were spatially different. The diameters of the 50% isodose curves differed 43% in the X axis and 32% in the Y axis for the Z =90 mm axial plane; by 44% in the X axis and 24% in the Z axis for the Y=90 mm coronal plane; and by 32% in the Z axis and 42% in the Y axis for the X=92 mm sagittal plane. The lack of ability of the GammaPlan to predict the rapid dose fall off, due to the air cavities behind or near the lesion led to an overestimation of the dose that was actually delivered. Clinically, this can result in underdosing of lesions near tissue inhomogeneities in patients under treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2718732DOI Listing

Publication Analysis

Top Keywords

gel dosimetry
16
gamma knife
12
tissue inhomogeneities
12
dose
11
dose distribution
8
planning system
8
homogeneous phantom
8
air cavities
8
inhomogeneous phantom
8
phantom dose
8

Similar Publications

The quantification of different structures, isoforms and types of damage in plasmid DNA is of importance for applications in radiation research, DNA based bio-dosimetry, and pharmaceutical applications such as vaccine development. The standard method for quantitative analysis of plasmid DNA damage such as single-strand breaks (SSB), double-strand breaks (DSB) or various types of base-damage is Agarose gel electrophoresis (AGE). Despite being well established, AGE has various drawbacks in terms of time consuming handling and analysis procedures.

View Article and Find Full Text PDF

Purpose: This study introduced a novel 3D dosimetry system for radiotherapy in order to address the limitations of traditional quality assurance methods in precision radiotherapy techniques.

Methods: The research required the use of scintillation material, optical measurements, and a dose reconstruction algorithm. The scintillation material, which mimics human soft tissue characteristics, served as a both physical phantom and a radiation detector.

View Article and Find Full Text PDF

Purpose: The purpose of this laboratory study was to evaluate common materials for isolation and neutralizing agents for hydrofluoric acid (HF). Additionally, surfaces of lithium disilicate ceramic were examined for precipitates after the etching and neutralizing process.

Materials And Methods: The HF permeability of the following isolation agents (n=8) was investigated by positioning them over pH indicator paper under airtight conditions and applying 9% HF: latex rubber dam; elastic plastomer rubber dam; nitrile gloves; latex gloves; liquid rubber dam; Teflon; AZ strip.

View Article and Find Full Text PDF

Development of TiF4-Dendrimer complex gel as an anti-demineralization agent for dentin: An in vitro study.

Dent Mater

February 2025

Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran; Restorative Dentistry Department, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran. Electronic address:

Objective: The anti-caries effects of titanium tetrafluoride (TiF4) are well-documented, but its low pH challenges clinical application. This study evaluated PEG-citrate dendrimer as a carrier to enhance TiF4 stability and efficacy.

Methods: PEG-citrate dendrimer and TiF4-dendrimer gel were synthesized, and their structures confirmed using Fourier Transform Infrared Spectroscopy (FTIR), Hydrogen Nuclear Magnetic Resonance (1H NMR), and Liquid Chromatography-Mass Spectrometry (LC-MS).

View Article and Find Full Text PDF

How much do we know about nanobacteria?

Ecotoxicol Environ Saf

December 2024

Acibadem Mehmet Ali Aydınlar University, Institute of Health Sciences, Department of Medical Biotechnology, Istanbul, Turkey; Acibadem Mehmet Ali Aydınlar University, School of Medicine, Department of Medical Microbiology, Istanbul, Turkey. Electronic address:

Background/purpose: Nanobacteria, known to date as self-replicating, nano-scale size organisms, smaller than bacteria. However, whether these are living organisms or agglomeration of biomolecules was one of the most controversial issues for many years. One of the reasons for debate is their lack of any genetic material.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!