A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Allometric scaling of biceps strength before and after resistance training in men. | LitMetric

Allometric scaling of biceps strength before and after resistance training in men.

Med Sci Sports Exerc

Department of Exercise Science and Health Promotion, Florida Atlantic University, Davie, FL 33314, and Division of Cardiology, Hartford Hospital, Hartford, CT, USA.

Published: June 2007

Purpose: The purposes of this study were 1) derive allometric scaling models of isometric biceps muscle strength using pretraining body mass (BM) and muscle cross-sectional area (CSA) as scaling variables in adult males, 2) test model appropriateness using regression diagnostics, and 3) cross-validate the models before and after 12 wk of resistance training.

Methods: A subset of FAMuSS (Functional SNP Associated with Muscle Size and Strength) study data (N=136) were randomly split into two groups (A and B). Allometric scaling models using pretraining BM and CSA were derived and tested for group A. The scaling exponents determined from these models were then applied to and tested on group B pretraining data. Finally, these scaling exponents were applied to and tested on group A and B posttraining data.

Results: BM and CSA models produced scaling exponents of 0.64 and 0.71, respectively. Regression diagnostics determined both models to be appropriate. Cross-validation of the models to group B showed that the BM model, but not the CSA model, was appropriate. Removal of the largest six subjects (CSA>30 cm) from group B resulted in an appropriate fit for the CSA model. Application of the models to group A posttraining data showed that both models were appropriate, but only the body mass model was successful for group B.

Conclusion: These data suggest that the application of scaling exponents of 0.64 and 0.71, using BM and CSA, respectively, are appropriate for scaling isometric biceps strength in adult males. However, the scaling exponent using CSA may not be appropriate for individuals with biceps CSA>30 cm. Finally, 12 wk of resistance training does not alter the relationship between BM, CSA, and muscular strength as assessed by allometric scaling.

Download full-text PDF

Source
http://dx.doi.org/10.1249/mss.0b013e3180423aadDOI Listing

Publication Analysis

Top Keywords

allometric scaling
16
scaling exponents
16
tested group
12
scaling
10
models
9
biceps strength
8
resistance training
8
scaling models
8
isometric biceps
8
body mass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!