Rapid accurate detection is a prerequisite for the successful control of meticillin-resistant Staphylococcus aureus (MRSA). The IDI-MRSA real-time polymerase chain reaction (PCR) assay was designed to provide rapid results from nasal specimens collected in Stuart's liquid transport medium. This study has evaluated the IDI-MRSA kit for use in a clinical laboratory by investigating the following parameters: (1) limits of detection (LoD), (2) performance with Amies' gel-based transport medium, (3) ability to detect strains of MRSA in a collection representative of MRSA in Ireland since 1974 (n=113) and (4) performance in a clinical trial with swabs from nose, throat and groin/perineum sites from 202 patients. LoDs (colony-forming units per ml) of the IDI-MRSA kit, direct culture on MRSA-Select chromogenic agar (CA) and salt-enrichment culture (with subculture onto CA) were 10(3), 10(3) and 10(2), respectively. LoDs with Stuart's and Amies' transport media were comparable. All except one of the 113 MRSA isolates were detected by the kit but, when six control strains carrying staphylococcal cassette chromosome mec (SCCmec) type IV element subtypes IVa-d and SCCmec types V and V(T) were tested, the kit failed to detect MRSA carrying SCCmec V. The sensitivity and specificity for detection of MRSA from nose, throat and groin/perineum specimens were comparable with slightly lower sensitivities from throat and groin/perineum specimens compared with nasal swabs (90%, 97%; 89%, 99%; 88%, 99%, respectively). Overall sensitivity, specificity and positive and negative predictive values for specimens from all sites were 88%, 99%, 94% and 97%, respectively. Further developments to improve the sensitivity of this highly worthwhile assay are required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10096-007-0303-7 | DOI Listing |
J Clin Microbiol
October 2008
National MRSA Reference Laboratory, St. James's Hospital, James's St., Dublin 8, Ireland.
The need for rapid methods to accurately detect methicillin-resistant Staphylococcus aureus (MRSA) is widely acknowledged, and a number of molecular assays are commercially available. This study evaluated the Xpert MRSA assay, which is run on the GeneXpert real-time PCR platform (Cepheid) for use in a clinical laboratory. The following parameters were investigated: (i) the limits of detection (LoDs) for four MRSA strains; (ii) the ability to detect isolates of MRSA from a collection representative of MRSA in Ireland since 1974 (n = 114) and the ability to detect control strains with staphylococcal cassette chromosome mec types IVa (IV.
View Article and Find Full Text PDFEur J Clin Microbiol Infect Dis
July 2007
National MRSA Reference Laboratory, St. James's Hospital, Dublin 8, Ireland.
Rapid accurate detection is a prerequisite for the successful control of meticillin-resistant Staphylococcus aureus (MRSA). The IDI-MRSA real-time polymerase chain reaction (PCR) assay was designed to provide rapid results from nasal specimens collected in Stuart's liquid transport medium. This study has evaluated the IDI-MRSA kit for use in a clinical laboratory by investigating the following parameters: (1) limits of detection (LoD), (2) performance with Amies' gel-based transport medium, (3) ability to detect strains of MRSA in a collection representative of MRSA in Ireland since 1974 (n=113) and (4) performance in a clinical trial with swabs from nose, throat and groin/perineum sites from 202 patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!