Purpose: We evaluated the influence of prior maximal exhalation on preoxygenation in 15 adult volunteers using tidal volume breathing (TVB) for five minutes and deep breathing (DB) for two minutes with and without prior maximal exhalation.

Methods: Inspired and end-tidal oxygen, nitrogen and carbon dioxide were monitored continuously and recorded during room air breathing and at 30-sec intervals during 100% oxygen TVB or DB (rate of 8 breaths.min(-1)).

Results: Tidal volume breathing with prior maximal exhalation resulted in an end-tidal oxygen concentration (ETO(2)) slightly higher (P = 0.028) at 0.5 and 1.0 min as compared with TVB without prior maximal exhalation at the same time periods. Regardless of whether TVB was preceded by maximal exhalation or not, 2.5 min was required to reach a mean ETO(2) value of 90% or higher. With DB, there were no differences in ETO(2) values at any time period and 1.5 min was required to reach an ETO(2) of 90% or greater, with or without prior maximal exhalation.

Conclusions: Maximal exhalation prior to TVB slightly steepens the initial rise in ETO(2) during the first minute, but confers no real benefit if maximal preoxygenation is the goal. Maximal exhalation prior to DB has no added value in enhancing preoxygenation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF03022030DOI Listing

Publication Analysis

Top Keywords

maximal exhalation
28
prior maximal
24
tidal volume
12
maximal
10
deep breathing
8
prior
8
volume breathing
8
end-tidal oxygen
8
min required
8
required reach
8

Similar Publications

Article Synopsis
  • The gold standard for measuring aerobic capacity in athletes is the VO2-max test, but it doesn't provide insights into muscular metabolic changes.
  • Near-infrared spectroscopy (NIRS) is a new technology that measures local oxygen levels in tissues, helping assess both breathing costs and muscle workload during exercise.
  • By analyzing changes in oxygen levels and tissue saturation, coaches and exercise physiologists can identify limitations in endurance training, improving athletic performance through tailored strategies.
View Article and Find Full Text PDF

Introduction: Physical inactivity due to shortness of breath is common among patients with uncontrolled asthma. We evaluated the body mass composition and exercise capacity of patients with poorly controlled asthma, despite maximal inhalation therapy.

Methods:  We recruited 56 patients from the Asthma Clinic of the University Hospital of Liège between September 2020 and December 2023, and 14 healthy subjects.

View Article and Find Full Text PDF

Middle Eastern countries, such as the United Arab Emirates and Oman, are affected by frequent dust storms and extreme hot climatic conditions, which can exacerbate respiratory conditions. These environmental factors are particularly injurious to asthmatic patients, as they can aggravate small airway disease (SAD), leading to increased morbidity and healthcare challenges. The evaluation of maximal mid-expiratory flow (MEF-25) as a diagnostic and therapeutic tool for early-stage small airway dysfunction is of significant clinical importance, particularly in hot and arid metropolitan environments where dusty conditions exacerbate pulmonary issues.

View Article and Find Full Text PDF

Background: The identification of volatile organic compounds (VOCs) in exhaled breath has garnered significant research attention as a means of screening and diagnosing lung cancer in recent decades. However, there is no universally accepted protocol for the collection of breath samples to measure VOCs in the clinical context. The purpose of this study was to summarize the current sampling techniques used to obtain VOCs from exhaled breath specifically in the context of lung cancer screening and diagnosis.

View Article and Find Full Text PDF

Highly sensitive and real-time detection of acetone biomarker for diabetes using a ZnO-coated optical fiber sensor.

Biosens Bioelectron

March 2025

International School of Engineering (ISE), Biomedical Materials and Devices for Revolutionary Integrative Systems Engineering Research Unit, Chulalongkorn University, Bangkok, 10330, Thailand. Electronic address:

This work presents a ZnO-coated no-core optical fiber sensor (OFS) designed for the highly sensitive detection of acetone vapor. Acetone is a key biomarker for diabetes, which is linked to blood glucose levels and can be detected non-invasively through breath analysis. The OFS utilizes a no-core fiber (NCF) as the sensing region, coated with a thin layer of ZnO nanoparticles to enhance evanescent field interaction with the VOCs at the fiber interface.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!