Background: The ability to measure carbon dioxide elimination (Vco(2)), oxygen uptake (Vo(2)), and R (respiratory exchange ratio, Vco(2)/Vo(2)) during anesthesia may help the non-invasive detection of critical events (e.g., abrupt decrease in cardiac output) and metabolic upset (e.g., onset of anaerobic metabolism).

Methods: We have developed a new clinical bymixer (inline mixing chamber) that can measure mixed inspired and expired gas fractions in the anesthesia circle circuit. The addition of a standard anesthesia gas analyzer and flowmeter, and a new airway temperature and humidity sensor, allow determinations of Vco(2) and Vo(2) at the airway opening of the circle circuit. Over a range of tidal volume and frequency, Vco(2) and Vo(2) were compared to reference values generated by the combustion of metered liquid ethanol in a new metabolic lung simulator.

Results: By linear regression, bymixer-flow measurements of Vco(2) (slope = 1.02, Y-intercept = -5.31, coefficient of determination, R(2) = 0.998) and Vo(2) (slope = 1.05, Y-intercept = -4.34, R(2) = 0.993) correlated closely to the reference values generated by the metabolic lung simulator. Limits of agreement analysis generated percent errors (mean +/- 1.96 SD) of -1.2 +/- 7.2% for Vco(2) and 2.5 +/- 9.8% for Vo(2).

Conclusions: The new clinical bymixer is compact, lightweight, disposable, inexpensive, and has a fast and adjustable response time (time constant about 14 sec). Anesthesia circle circuit integrity is maintained. Bymixer-flow measurements of Vco(2) and Vo(2) are accurate and may add to clinical monitoring under anesthesia and surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF03022028DOI Listing

Publication Analysis

Top Keywords

circle circuit
16
anesthesia circle
12
vco2 vo2
12
clinical bymixer
8
reference values
8
values generated
8
metabolic lung
8
bymixer-flow measurements
8
measurements vco2
8
anesthesia
6

Similar Publications

An Optimized Version of the Small Synthetic Genome (Mini-Synplastome) for Plastid Metabolic Engineering in (Potato).

ACS Synth Biol

December 2024

Center for Agricultural Synthetic Biology (CASB), University of Tennessee, 2640 Morgan Circle Dr., Knoxville, Tennessee 37996, United States.

Plastids represent promising targets in plant genetic engineering for many biotech applications, ranging from their use as bioreactors for the overproduction of valuable molecules to the installation of transgenes for improving plant traits. For over 30 years, routine methods of plastid transformation have relied on homologous recombination integrating vectors. However, nonintegrating episomal plasmids have recently received more attention as an innovative tool for the plastid genetic engineering of plant cells.

View Article and Find Full Text PDF

Neuroligin 1 Regulates Autistic-Like Repetitive Behavior through Modulating the Activity of Striatal D2 Receptor-Expressing Medium Spiny Neurons.

Adv Sci (Weinh)

December 2024

The Key Laboratory of Developmental Genes and Human Disease, The School of Life Science and Technology, Southeast University, 2 Sipailou Road, Nanjing, 210096, China.

Restricted and repetitive behavior (RRB) is a primary symptom of autism spectrum disorder (ASD), which poses a significant risk to individuals' health and is becoming increasingly prevalent. However, the specific cellular and neural circuit mechanisms underlying the generation of RRB remain unclear. In this study, it is reported that the absence of the ASD-related protein Neuroligin 1 (NLGN1) in dopamine receptor D2-expressing medium spiny neurons (D2-MSNs) in the dorsal striatum is associated with the duration and frequency of self-grooming and digging behaviors.

View Article and Find Full Text PDF

The circle breathing system enables rebreathing using a carbon dioxide absorbent. This case report presents a rare incident of ventilation failure in a 30-year-old male patient due to a broken unidirectional valve in a soda lime canister. Despite the anesthesia machine passing automated checks, a mechanical blockage from caked soda lime in the inner inspiratory chamber led to insufficient tidal volume delivery.

View Article and Find Full Text PDF

This paper presents a self-powered biosensing platform based on graphdiyne@Au (2D GDY@Au) nanoparticles and rolling circle-hybridization chain (RC-HC) dual linear cascade amplification technology, which significantly enhances target recognition and signal amplification efficiency for miRNA-141. Specifically, the target on bioanode outputs a large amount of single-stranded DNA (T1) through the strand displacement amplification (SDA) mechanism. This efficient target recycling process triggers RC-HC dual linear cascade reaction.

View Article and Find Full Text PDF

Development of flip-chip technology for the optical drive of superconducting circuits.

Open Res Eur

November 2024

Quantum Electronics, Physikalisch-Technische Bundesanstalt, Braunschweig, Lower Saxony, 38116, Germany.

We discuss the flip-chip mounting process of photodiodes and fiber sleeves on silicon substrates to meet the increasing demand for fabrication of highly integrated and hybrid quantum circuits for operation at cryogenic temperatures. To further increase the yield and success rate of the flip-chip procedure, the size of the gold stud bumps, and flip-chip parameters were optimized. Moreover, to connect optical fibers to the photodiodes in an optimal position, the fiber sleeves were aligned with specially fabricated alignment circles before applying thermocompression with the flip-chip machine.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!