The surgeon must determine the pathologic elements that need correction. Close observation for an increased HV angle, increased IM angle, pronation of the first toe, increased DMAA, enlarged medial eminence, and subluxation of the sesamoids must be performed. While there are a large number of procedures available for the management of HV, no one method sufficiently corrects all HV deformities. The upper limits of deformity correction for each procedure vary with the surgeon and their familiarity with each procedure. Ultimately, the surgeon must attempt to maintain a flexible first MTP joint and preserve the normal weightbearing pattern of the forefoot. Patient education also can be assistive in avoiding aggravating activities and making better choices in shoe wear. Tracings of the weightbearing foot and the shoe can be used to demonstrate to patients the size differences between the natural size and shape of the foot and that of the shoe, both pre- and postoperatively.
Download full-text PDF |
Source |
---|
Sci Rep
January 2025
Department of Orthopaedic, South China Hospital of Shenzhen University, Shenzhen, 518116, Guangdong, China.
Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.
View Article and Find Full Text PDFSci Rep
January 2025
Geotechnical and Mining Engineering Division, University of Western Macedonia, Kozani, Greece.
Tunnel stability is a critical factor in complex geological conditions, particularly in rock masses with steeply dipping layers. Among widely used methods, the Convergence-Confinement Method (CCM), a prevalent two-dimensional (2D) approach, effectively captures the relaxation process preceding support installation. However, most studies focus on homogeneous or horizontally layered rock masses, often overlooking the influence of steeply dipping, and layered geological formations.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.
We aimed to analyze the cervical sagittal alignment change following the growing rod treatment in early-onset scoliosis (EOS) and identify the risk factors of sagittal cervical imbalance after growing-rod surgery of machine learning. EOS patients from our centre between 2007 and 2019 were retrospectively reviewed. Radiographic parameters include the cervical lordosis (CL), T1 slope, C2-C7 sagittal vertical axis (C2-7 SVA), primary curve Cobb angle, thoracic kyphosis (TK), C7-S1 sagittal vertical axis (C7-S1 SVA) and proximal junctional angle (PJA) were evaluated preoperatively, postoperatively and at the final follow-up.
View Article and Find Full Text PDFJ Prosthodont Res
January 2025
Department of Comprehensive Dentistry, UT Health San Antonio, San Antonio, USA.
Purpose: To determine the effects of K18 quaternary ammonium methacryloxy silane (QAS) on tissue conditioner materials and their antimicrobial properties.
Methods: 30% K18 QAS in methyl methacrylate (MMA; K18-MMA; 0%, 15%, and 20% w/w) was incorporated into a commercial tissue conditioner (Coe comfort). The degree of curing (Shore A hardness), hydrophilicity (contact angle), flow, liquid sorption, mass loss, and antimicrobial properties of Streptococcus mutans, Streptococcus sanguinis, and Candida albicans were determined.
J Prosthodont Res
January 2025
Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen.
Purpose: This systematic review evaluated the effect of different printing orientations on the physical-mechanical properties and accuracy of resin denture bases and related specimens.
Study Selection: Utilizing PRISMA 2020 guidelines, a comprehensive search of PubMed, Web of Science, Cochrane, and Scopus databases was conducted until June 2024. Included studies examined the accuracy, volumetric changes, and mechanical or physical properties of 3D-printed denture bases in various orientations.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!