Objectives: To evaluate cytotoxicity and bactericidal effects of chloramine-T.
Methods: In vitro study of various concentrations and exposure times to preparations containing human fibroblasts or 1.5 x 10 colony forming units per milliliter (CFU/mL) of 3 gram-positive bacteria-Staphylococcus aureus, methicillin-resistant S aureus, and vancomycin-resistant Enterococcus faecalis-and 2 gram-negative bacteria-Escherichia coli and Pseudomonas aeruginosa-with and without fetal bovine serum present.
Main Outcome Measures: Percentage reduction of bacterial growth and percentage of viable fibroblasts 48 hours after exposure.
Results: All gram-positive growth was reduced by 95% to 100%, regardless of dose, with or without serum. E coli (gram-negative; with/without serum) was reduced 94% to 100% at antiseptic concentrations of 300 and 400 ppm. At 200 ppm, E coli growth was fully inhibited without serum present and by 50% with serum. P aeruginosa (gram-negative) was not significantly affected under any conditions. At 100 and 200 ppm, cell viability remained greater than 90% under all experimental conditions. A 300-ppm, 3-minute exposure to chloramine-T resulted in cell viability of up to 70%, with longer exposures producing lower viabilities. Serum did not affect cell viability in any condition.
Conclusions: In vitro, chloramine-T at 200 ppm for 5 to 20 minutes was effective against 3 virulent gram-positive bacteria without fibroblast damage. At 300 ppm and 3 and 5 minutes, 30% of fibroblasts were damaged and 95% to 100 % of E coli were inhibited, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.ASW.0000276408.53632.0b | DOI Listing |
Anal Chim Acta
February 2025
School of Physics and Electronic Information Engineering, Henan Polytechnic University, Jiaozuo, 454003, China. Electronic address:
Background: Trimethylamine (TMA) is a colorless, volatile gas with a strong irritating odor. Prolonged exposure to a certain amount of TMA can cause symptoms such as dizziness, nausea and difficulty breathing, and may even be life-threatening. Therefore, effective detection of TMA is crucial.
View Article and Find Full Text PDFAnimal
December 2024
Department of Ruminant Science, Institute of Animal Science, Agricultural Research Organization, Rishon Lezion 7528809, Israel. Electronic address:
Use of desalinated seawater in arid and semiarid regions for domestic, industrial, and agricultural purposes is on the rise. Consequently, in those regions, drinking water offered to lactating cows has lower salinity and mineral concentrations than in the past. Although water with total dissolved solids (TDSs) of up to 1 000 ppm is considered safe for drinking, lower salinity level may affect rumen physiology, feed and water intake, or milk yield.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland.
Cyclic voltammetry (CV) can be applied as a reliable method for the determination of chloride ions in a range from several to a couple hundred (about 200) ppm. Since the standard potential of chloride ion/gaseous chlorine is 1.36 V vs.
View Article and Find Full Text PDF3 Biotech
February 2025
Department of Pharmacology, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, Karnataka 576104 India.
This study is aimed at evaluating the neurotoxic effects of chronic exposure of sodium fluoride (NaF) in developmental stages in rat using prenatal models. NaF (100 ppm, orally) dosing via drinking water was given to pregnant rats in disease group. In the treatment groups, Metformin & Dehydrozingerone (DHZ) (200 mg/kg) were administered orally along with NaF, and the dosing was continued throughout the gestation and lactation periods to the pups until the end of experiment.
View Article and Find Full Text PDFAnal Bioanal Chem
January 2025
Department of Plant and Environmental Science, University of Copenhagen, Thorvaldsensvej 40, DK-1871, Frederiksberg, Denmark.
Liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) is commonly used for identification of compounds in complex samples due to the high chromatographic and mass spectral resolution provided. In subsequent data processing workflows, it is imperative to preserve this resolution to fully exploit the data. "Region of interest" (ROI) algorithms were introduced as a better alternative to equidistant binning for compressing HRMS data because they better preserve the mass spectral resolution.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!