The DD-System is a dose-distribution system for analyzing the film method with a general-purpose flatbed image scanner. By analyzing the analogue digital conversion(ADC)value of each pixel acquired by the DD-system, we examined the technical problems of measurement with the scanner when making a dose-density table. When film of uniform density was measured, the ADC values distributed normally. Deviation of the values at the same pixel point on another time was about one-ten thousandth of the average. Deviation of the values from the time the scanner was turned on was in the same range. Although it may be negligible, the values measured at a peripheral area on the flatbed deviated about 2SD from the average measured at the central area. Further, deviation of the value obtained with a shade covering the outside of the irradiation field from that taken without the shade was about one thousandth. These deviations are not negligible. In the case of making a dose-density table with a DD-System and a general-purpose flatbed image scanner, the film should be set in the center of the flatbed, and the sampling area should be selected from those areas where the ADC values are distributed normally. Then proper data can be obtained and more accurate tables can be made.

Download full-text PDF

Source
http://dx.doi.org/10.6009/jjrt.63.595DOI Listing

Publication Analysis

Top Keywords

general-purpose flatbed
12
flatbed image
12
image scanner
12
making dose-density
12
scanner making
8
dose-density table
8
adc values
8
values distributed
8
deviation values
8
flatbed
5

Similar Publications

The DD-System is a dose-distribution system for analyzing the film method with a general-purpose flatbed image scanner. By analyzing the analogue digital conversion(ADC)value of each pixel acquired by the DD-system, we examined the technical problems of measurement with the scanner when making a dose-density table. When film of uniform density was measured, the ADC values distributed normally.

View Article and Find Full Text PDF

A novel technique for modeling microscopic anatomical structures in three dimensions was developed as part of a survey of gekkonid laryngeal skeletal morphology (Reptilia: Gekkonidae). Excised larynges were transversely sectioned at 10 microns and stained using standard procedures. With a projection microscope, outline drawings of the sectioned laryngeal cartilages were made at regular intervals, depending on the rate and degree of structural change observed while sampling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!