Interventional procedures in MRI can be performed preclinically using active or passive catheter-tracking methods. A novel passive nonproton technique is suggested that uses a catheter filled with a hyperpolarized (13)C contrast agent. A prototype three-lumen catheter was built with two closed lumens containing a flowing hyperpolarized (13)C contrast agent. Entire-length (13)C catheter projection visualization could be performed in vivo with a catheter SNR of approximately 80, one dual projection frame per approximately 700 ms, and an in-plane resolution of 2 x 2 mm(2) while traveling through the aorta of a pig. The traveling path of the (13)C catheter was visualized after back-projection catheter reconstruction and after image fusion with an anatomical offline proton road map. Catheter length visualization was aided by an oblique planar visualization mode. The high catheter signal demonstrated, together with the entire catheter length visualization and high surrounding soft-tissue contrast, warrants further development into a real-time technique.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.21239DOI Listing

Publication Analysis

Top Keywords

hyperpolarized 13c
12
catheter
9
13c contrast
8
contrast agent
8
13c catheter
8
catheter length
8
length visualization
8
13c
5
passive catheter
4
catheter tracking
4

Similar Publications

: Pancreatic ductal adenocarcinoma (PDAC) is a highly lethal malignancy with a five-year survival rate of approximately 13% for advanced stages. While the majority of PDAC cases are sporadic, a significant subset is attributable to hereditary and familial predispositions, accounting for approximately 25% of cases. This article synthesizes recent advancements in the understanding, detection, and management of hereditary pancreatic cancer (PC).

View Article and Find Full Text PDF

Spatially constrained hyperpolarized 13C MRI pharmacokinetic rate constant map estimation using a digital brain phantom and a U-Net.

J Magn Reson

January 2025

UC Berkeley - UCSF Graduate Program in Bioengineering, 1700 4th St, San Francisco, CA 94158, USA; Radiology and Biomedical Imaging, University of California, San Francisco, 1700 4th St, San Francisco, CA 94158, USA.

Fitting rate constants to Hyperpolarized [1-C]Pyruvate (HP C13) MRI data is a promising approach for quantifying metabolism in vivo. Current methods typically fit each voxel of the dataset using a least-squares objective. With these methods, each voxel is considered independently, and the spatial relationships are not considered during fitting.

View Article and Find Full Text PDF

Nuclear magnetic resonance (NMR) spectroscopy is a valuable diagnostic tool limited by low sensitivity due to low nuclear spin polarization. Hyperpolarization techniques, such as dissolution dynamic nuclear polarization, significantly enhance sensitivity, enabling real-time tracking of cellular metabolism. However, traditional high-field NMR systems and bioreactor platforms pose challenges, including the need for specialized equipment and fixed sample volumes.

View Article and Find Full Text PDF

The achievable spatial resolution of C metabolic images acquired with hyperpolarized C-pyruvate is worse than H images typically by an order of magnitude due to the rapidly decaying hyperpolarized signals and the low gyromagnetic ratio of C. This study is to develop and characterize a volumetric patch-based super-resolution reconstruction algorithm that enhances spatial resolution C cardiac MRI by utilizing structural information from H MRI. The reconstruction procedure comprises anatomical segmentation from high-resolution H MRI, calculation of a patch-based weight matrix, and iterative reconstruction of high-resolution multi-slice C MRI.

View Article and Find Full Text PDF

NMR is a central tool in the field of metabolomics, thanks to its ability to provide valuable structural and quantitative information with high precision. Most NMR-based metabolomics studies rely on 1D H detection, which is heavily limited by strong peak overlap. C NMR benefits from a wider spectral dispersion and narrower signal line width but is barely used in metabolomics due to its low sensitivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!