Purpose: To evaluate and compare anterior chamber depth (ACD) measurements using Orbscan II (Bausch & Lomb, Rochester, NY) and IOLMaster (Carl Zeiss Meditec AG, Jena, Germany).

Methods: In this prospective clinical study, the authors measured ACD of 145 phakic eyes of 30 healthy volunteers and 115 patients using Orbscan II and IOLMaster. Average patient age was 52.9+/-19.4 (range 16 to 87) years. ACD was evaluated from corneal epithelium to anterior lens surface. Additionally, axial length (AL) was measured using the Zeiss IOLMaster to calculate the regression coefficient between AL and ACD.

Results: Mean ACD was 3.35+/-0.43 mm (range 2.01 mm to 4.37 mm) using Orbscan II and 3.36+/-0.41 mm (range 2.09 mm to 4.24 mm) using IOLMaster. Mean total axial length was 24.04 mm +/- 2.1 mm (range 20.7 mm to 31.41 mm). The linear regression coefficient of ACD between both methods was R=0.95. ACD and AL correlated only slightly (R=0.57). The Spearman coefficients of rank correlation were 0.94 and 0.61, respectively. A p value less than 0.01 (paired Wilcoxon test) was considered statistically significant. However, a significant difference was not calculated comparing ACD measurements using both systems and the Bland-Altman-Plot showed 95% of the differences ranging between 0.25 and -0.27 mm.

Conclusions: Regarding clinical application, both systems seem to be equally good and interchangeable in clinical practice in terms of ACD evaluation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/112067210701700308DOI Listing

Publication Analysis

Top Keywords

anterior chamber
8
chamber depth
8
measurements orbscan
8
orbscan iolmaster
8
acd
8
acd measurements
8
axial length
8
regression coefficient
8
iolmaster
5
comparison anterior
4

Similar Publications

Extracellular vesicles (EVs) are lipid bilayer particles released by virtually all cells, with prominent roles in both physiological and pathological processes. The size, number, and molecular composition of released EVs correlate to the cells of origin, modulated by the cell's environment and pathologic state. The proteins, DNA, RNA, and protein cargo carried by EVs are protected by degradation, with a prominent role in targeted intercellular signaling.

View Article and Find Full Text PDF

Aflibercept and brolucizumab, two anti-VEGF agents used as intravitreal injections in ophthalmology, differ significantly in molecular weight (aflibercept-115 kDa and brolucizumab-26 kDa). Using aqueous humor samples collected after drug administration, we measured and performed a comparative analysis of pharmacokinetics and half-lives of these drugs in the human eye. Since the quantification of monoclonal antibodies (mAbs) using antigen-antibody reactions, such as ELISA, is influenced by endogenous ligands or anti-drug antibodies, we employed nano-surface and molecular-orientation limited proteolysis (nSMOL), combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS), for accurate measurements.

View Article and Find Full Text PDF

Coronary artery fistulas (CAFs) are rare congenital anomalies, presenting in 0.05-0.9% of cases, characterized by an aberrant connection between a coronary artery and a cardiac chamber or great vessel.

View Article and Find Full Text PDF

Background: Endothelin is a potent vasoconstrictor and contributes to the regulation of vascular perfusion. Aberrant endothelin-1 (ET-1) levels in aqueous humor have been reported across a variety of vascular diseases of the eye, including glaucoma. These findings suggest that dysregulation of ET-1 production may contribute to glaucoma pathophysiology.

View Article and Find Full Text PDF

Purpose: A human model able to simulate the manifestation of corneal endothelium decompensation could be advantageous for wound healing and future cell therapy assessment. The study aimed to establish an ex vivo human cornea endothelium wound model where endothelium function can be evaluated by measuring corneal thickness changes.

Methods: The human cornea was maintained in an artificial anterior chamber, with a continuous culture medium infusion system designed to sustain corneal endothelium and epithelium simultaneously.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!