A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification. Observational study. | LitMetric

Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification. Observational study.

J Cataract Refract Surg

Iladevi Cataract & IOL Research Centre, Raghudeep Eye Clinic, Gurukul Road, Memnagar, Ahmedabad-380052, India.

Published: June 2007

Purpose: To evaluate the intraoperative performance and postoperative outcomes after microcoaxial phacoemulsification.

Setting: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.

Methods: A prospective observational case series comprised 84 eyes with age-related uncomplicated cataract having microcoaxial phacoemulsification through a 2.2 mm clear corneal incision by a standard surgical technique. Phacoemulsification parameters (Infiniti Vision System, Alcon) were microburst width, 30 ms; preset power, 50%; vacuum, 650 mm Hg; aspiration flow rate, 25 cc/minute. A single-piece Alcon AcrySof intraocular lens was implanted with the C cartridge (Alcon) cartridge. The incision was measured at the end of surgery. Observations included surgical time (from commencement of sculpting to end of epinucleus removal), cumulative dissipated energy (CDE), wound burns, intraoperative complications, postoperative increase in mean central corneal thickness (CCT) at 1 day and 1 month, mean % decrease in endothelial cell density (ECD), absolute mean change in coefficient of variation (cv) 3 months, and uncorrected visual acuity (UCVA) at 1 day. Data were analyzed using a 1-sample t test with 95% confidence intervals (CIs).

Results: The mean follow up was 3 months +/- 0.3 (SD). The mean incision size at the end of surgery was 2.3 +/- .09 mm; mean surgical time, 4.5 +/- 1.5 minutes; and mean CDE, 2.3 +/- 2.2 seconds. No wound burns or other intraoperative complications occurred. The postoperative CCT increased by a mean of 16 microm at 1 day (95% CI, 8-25; P = .66;) and by a mean of 3.14 microm at 1 month (95% CI, 2.26-4.05; P = .92). The ECD decreased by a mean of 5.8% (95% CI, 6.8-3.5; P = .82) and the mean coefficient of variation, by 3.3 (95% CI, 4.5-2.0; P = .65). At 1 day, the UCVA was 20/20 in 29% of cases, 20/20 to 20/40 in 58%, and 20/40 to 20/50 in 12%.

Conclusion: Microcoaxial phacoemulsification was safely and effectively performed, achieving consistent and satisfactory postoperative outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2007.02.029DOI Listing

Publication Analysis

Top Keywords

postoperative outcomes
12
microcoaxial phacoemulsification
12
intraoperative performance
8
performance postoperative
8
outcomes microcoaxial
8
surgical time
8
wound burns
8
burns intraoperative
8
intraoperative complications
8
coefficient variation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!