The diagnostic and prognostic value of symptom limited exercise tests (ET) performed before discharge and after one month were compared in men admitted to hospital after an episode of unstable angina or a non-Q-wave myocardial infarction (MI). A 'Positive ET' was defined as either a maximal work load below 100 W or ST-depression greater than or equal to 0.1 mV in 1-2 leads below 130 W or ST-depression greater than or equal to 0.1 mV in more than 2 leads at any load at the ET. During follow-up, severe angina was the only indication for coronary angiography and revascularization. There were no significant differences in diagnostic findings between the tests--Positive ET in 47% and Negative ET in 25% at both ETs. The occurrence of MI or death and the need of revascularization were related to signs of ischemia at both ETs. There were no differences in prognostic value between the early and late tests regarding MI or death or future severe angina during the 11 months' follow-up after the one month ET. However, half (10%) of the overall event rate (20%) during the one year follow-up occurred during the first months. The risk of these events could be identified by the predischarge but, for obvious reasons, not by the one month ET. Therefore, the present study suggests that a symptom limited ET should be performed before discharge in men stabilized after an episode of unstable angina or non-Q-wave MI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF01797676 | DOI Listing |
Eur J Pediatr
January 2025
Institute of Clinical Research, University of Southern Denmark, Odense, Denmark.
Unlabelled: In very preterm-born infants, nutritional intake is important to reduce the risk of severe metabolic bone disease including the risk of a lower bone mineral density (BMD). The aim of this study was to evaluate bone mineral content (BMC) and BMD (measured as BMC per bone area (BA)) at six years of age in very preterm-born infants fed different diets post-discharge. Data on this topic so far is insufficient, and with this study we aim to supply more useful data.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
Department of Plasma Physics and Fusion Engineering, University of Science and Technology of China, Hefei 230026, China.
A novel all-fiber optic current sensor (FOCS) is designed specifically for the measurement of large transient currents based on the Faraday effect. A reciprocal symmetric structure is incorporated into the optical sensing loop, and the current dependent phase demodulation is achieved by using a passive optical fiber coupler and the homodyne detection scheme. This design offers several advantages, including structural simplicity, high voltage insulation, low noise, high linearity, and excellent frequency response, and is highly suitable for use in any system of high-voltage, high-power, and high-frequency in nature.
View Article and Find Full Text PDFWater Sci Technol
January 2025
The Institute of Applied Research, The Galilee Society, Shefa-Amr 2020000, Israel; Agrobics Ltd, Shefa-Amr 2020000, Israel; Prof. Ephraim Katzir Department of Biotechnology Engineering, Braude College of Engineering, Karmiel 2161002, Israel.
The advanced anaerobic technology (AAT), developed based on an immobilized high-rate anaerobic reactor, was applied as a pretreatment of municipal wastewater (WW) at Karmiel's treatment plant in Israel. The demonstration-scale AAT (21 m) system was operated at a flow rate of 100 mday municipal WW mixed with olive mill wastewater (OMW) (0.5 mday) to simulate the scenario of illegal discharge of agro-industrial WW.
View Article and Find Full Text PDFAnal Chem
January 2025
Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China.
Field analysis of heavy metals in biological samples is essential for assessing their potential threats to human health. The development of portable pretreatment and detection devices is crucial to address this challenge. Herein, a magnetic field-accelerated nonthermal plasma digestion device using dielectric barrier discharge (DBD) is designed for the rapid and environmentally friendly pretreatment of biological samples and subsequently combined with point discharge-optical emission spectrometry (PD-OES) for sensitive determination of heavy metals.
View Article and Find Full Text PDFStroke
January 2025
Northwell Health, New Hyde Park, NY (N.G.F., M.X.S., J.O.H., S.R.F., J.J.W., J.M.K., P.C.S.).
Background: Many national initiatives focus on promoting early hospital arrival of patients with acute ischemic stroke (AIS) because treatment effectiveness is time-dependent. However, several studies reported time-delays in hospital arrival, especially during the COVID-19 pandemic. Our purpose was to evaluate the 10-year trends in last known well to arrival (LKWA) time and assess disparities in patients with AIS.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!