The representation of human movement requires knowledge of both movement and morphology of bony segments. The determination of subject-specific morphology data and their registration with movement data is accomplished through an anatomical calibration procedure (calibrated anatomical systems technique: CAST). This paper describes a novel approach to this calibration (UP-CAST) which, as compared with normally used techniques, achieves better repeatability, a shorter application time, and can be effectively performed by non-skilled examiners. Instead of the manual location of prominent bony anatomical landmarks, the description of which is affected by subjective interpretation, a large number of unlabelled points is acquired over prominent parts of the subject's bone, using a wand fitted with markers. A digital model of a template-bone is then submitted to isomorphic deformation and re-orientation to optimally match the above-mentioned points. The locations of anatomical landmarks are automatically made available. The UP-CAST was validated considering the femur as a paradigmatic case. Intra- and inter-examiner repeatability of the identification of anatomical landmarks was assessed both in vivo, using average weight subjects, and on bare bones. Accuracy of the identification was assessed using the anatomical landmark locations manually located on bare bones as reference. The repeatability of this method was markedly higher than that reported in the literature and obtained using the conventional palpation (ranges: 0.9-7.6 mm and 13.4-17.9, respectively). Accuracy resulted, on average, in a maximal error of 11 mm. Results suggest that the principal source of variability resides in the discrepancy between subject's and template bone morphology and not in the inter-examiner differences. The UP-CAST anatomical calibration could be considered a promising alternative to conventional calibration contributing to a more repeatable 3D human movement analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gaitpost.2007.04.009 | DOI Listing |
Med Biol Eng Comput
January 2025
Mechanical Engineering Department, Tianjin University, No. 135, Yaguan Road, Haihe Education Park, Jinnan District, Tianjin City, 300350, China.
The use of AR technology in image-guided neurosurgery enables visualization of lesions that are concealed deep within the brain. Accurate AR registration is required to precisely match virtual lesions with anatomical structures displayed under a microscope. The purpose of this work was to develop a real-time augmented surgical navigation system using contactless line-structured light registration, microscope calibration, and visible optical tracking.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Plant Experimental Biology, Faculty of Science, Charles University, Viničná 5, 12800, Prague, Czech Republic.
A wide range of portable chlorophyll meters are increasingly being used to measure leaf chlorophyll content as an indicator of plant performance, providing reference data for remote sensing studies. We tested the effect of leaf anatomy on the relationship between optical assessments of chlorophyll (Chl) against biochemically determined Chl content as a reference. Optical Chl assessments included measurements taken by four chlorophyll meters: three transmittance-based (SPAD-502, Dualex-4 Scientific, and MultispeQ 2.
View Article and Find Full Text PDFPLoS Comput Biol
January 2025
Department of Mechanical Engineering, University of California Riverside, Riverside, California, United States of America.
Respiratory diseases represent a significant healthcare burden, as evidenced by the devastating impact of COVID-19. Biophysical models offer the possibility to anticipate system behavior and provide insights into physiological functions, advancements which are comparatively and notably nascent when it comes to pulmonary mechanics research. In this context, an Inverse Finite Element Analysis (IFEA) pipeline is developed to construct the first continuously ventilated three-dimensional structurally representative pulmonary model informed by both organ- and tissue-level breathing experiments from a cadaveric human lung.
View Article and Find Full Text PDFClin Chem Lab Med
January 2025
Pathology & Anatomical Sciences, University of Missouri, Columbia MO, USA.
Objectives: C-peptide is an equimolar by-product of insulin biosynthesis. It is used clinically to assess insulin secretion and differentiate types of diabetes. However, the lack of standardization across assays limits its broader application.
View Article and Find Full Text PDFAm J Cancer Res
December 2024
Department of Ultrasound, The Second People's Hospital, Fujian University of Traditional Chinese Medicine Fuzhou 350003, Fujian, China.
Background: Ultra-low rectal endoscopic submucosal dissection (ESD) presents technical challenges due to anatomical features. The objective of this research was to determine the risk factors linked to unsuccessful curative resections and to create a nomogram predictive model to assess the likelihood of encountering technical challenges.
Methods: Patients with ultra-low rectal tumors received ESD form June 2017 to December 2022 were retrospectively enrolled.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!