Purpose: Schültze, in 1866, originally proposed that macular pigment (MP) could improve acuity by reducing the deleterious effects associated with the aberration of short-wave (SW) light. Although proposed well more than a century ago, the hypothesis has never been empirically tested. The authors chose to begin evaluating the acuity hypothesis by measuring MP levels, gap, and hyperacuity in the same observers.

Methods: Eighty healthy young subjects were assessed. Forty subjects were assigned to the gap acuity experiment and 40 to the hyperacuity experiment. Peak MP optical density (MPOD) was measured using heterochromatic flicker photometry (HFP). Resolution and hyperacuity were measured as the minimum perceivable gap between two solid black lines (1'' width) vertically separated and as a vernier offset, respectively. These targets were presented on a 0.5 degrees circular diffusing background that appeared either white (17 cd/m2) or yellow (16 cd/m2). The yellow background was produced by using light-emitting diodes (LEDs) with a peak lambda = 570 nm. The white background was produced by combining the yellow with a blue LED (peak lambda = 460 nm). The subject's head (5.33 m from the stimulus) was stabilized with a head-rest assembly, and the adaptive state was controlled with the use of a constant white surround (11 cd/m2). Thresholds were determined based on probit analysis of psychometric functions generated using a two-alternative forced-choice procedure.

Results: MPOD ranged from 0.14 to 1.00 measured at 30' eccentricity. Gap and hyperacuity measures each varied by a factor of approximately 5 to 6. Average gap acuity (N = 38) for the white condition (filtered by MP) was 31.2'' (SD = 9.4) and did not differ from the average (N = 38) for the yellow condition (not filtered by MP), which was 32.1'' (SD = 10.9). Similarly, average hyperacuity for the white condition (7.0''; SD = 2.9) did not differ from that of the yellow condition (6.8''; SD = 3.5).

Conclusions: MPOD did not correlate significantly with gap or hyperacuity measured in the yellow or white conditions. These data, therefore, do not support the predictions of the acuity hypothesis.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.06-0883DOI Listing

Publication Analysis

Top Keywords

acuity hypothesis
12
gap hyperacuity
12
macular pigment
8
gap acuity
8
hyperacuity measured
8
cd/m2 yellow
8
background produced
8
peak lambda
8
white condition
8
condition filtered
8

Similar Publications

Schwannomas (SCs) are benign tumors composed of neoplastic Schwann cells and are relatively uncommon intracranially. Although these tumors are frequently associated with neurofibromatosis type 2 (NF2), they may also arise idiopathically, and their pathogenesis remains poorly understood. A 70-year-old Caucasian man presented with a two-month history of vertigo, gait imbalance, and decreased visual acuity in the left eye accompanied by photophobia, nausea, vomiting, and occasional headaches.

View Article and Find Full Text PDF

To present a pediatric patient with a unique configuration of torpedo maculopathy complicated by macular choroidal neovascularization (CNV). A single case was retrospectively reviewed. An 8-year-old male child presented with decreased vision in the left eye and was found to have 2 distinct torpedo maculopathy lesions, 1 a smaller hypopigmented lesion in the temporal parafovea and the other a larger hyperpigmented comet-shaped lesion in the temporal periphery.

View Article and Find Full Text PDF

The fovea, a pit in the retina, is crucial for high-acuity vision in humans and is found in the eyes of other vertebrates, including certain primates, birds, lizards, and fish. Despite its importance for vision, our understanding of the mechanisms involved in fovea development remains limited. Widely used ocular research models lack a foveated retina, and studies on fovea development are mostly limited to histological and molecular studies in primates.

View Article and Find Full Text PDF

Purpose: The foveal avascular zone (FAZ) area has been explored as a measure of macular ischemia in diabetic retinopathy (DR) but is limited by its wide variability even in healthy individuals. We hypothesized that FAZ enlargement, which we defined as the difference between the functional FAZ (on optical coherence tomography angiography; OCTA) and structural FAZ (en face OCT), may be a more accurate metric of macular ischemia. In this study, we test the hypothesis that FAZ enlargement is associated with decreased best-corrected visual acuity (BCVA) and low luminance visual acuity (LLVA) and performs better than the functional FAZ as a marker of vision loss.

View Article and Find Full Text PDF

Proprioceptive acuity for locating and controlling movements of a hand-held tool.

Neuroscience

January 2025

Department of Health and Human Physiology, Motor Control Laboratory, University of Iowa, 225 S. Grand Avenue, Iowa City, IA 52242, United States.

We investigated proprioceptive acuity for location and motion of a never seen hand-held tool (30 cm long rod) and the accuracy of movements to place tool parts in the location of remembered visual targets. Ten blindfolded right-handed subjects (5 females) reached with the tool held in the right hand to touch the tip and midpoint to the stationary and moving left index-tip, to the right and left ear lobes and to remembered visual target locations. We also tested accuracy of left hand rod reaches to the ear lobes to determine if rod dimensions and control of tool movements experienced during right hand tool use could be used to accurately localize the rod parts when held in the left hand.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!