Supported by the European Commission, the EVIDOS project started in November 2001 with the broad goal of evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry. Seven European institutes joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A comprehensive programme was devised to evaluate capabilities and limitations of standard and innovative personal dosemeters in relation to the mixed neutron-photon fields of concern to the nuclear industry. This paper describes the criteria behind the selection of dosimetry techniques and workplaces that were analysed, as well as the organisation of the measurement campaigns. Particular emphasis was placed on the evaluation of a variety of electronic personal dosemeters, either commercially available or previously developed by the partners. The estimates provided by these personal dosemeters were compared to reference values of dose equivalent quantities derived from spectrometry and fluence-to-dose equivalent conversion coefficients. Spectrometry was performed both with conventional multisphere and with some original instrumentation providing energy and direction resolution, based on silicon detectors and superheated drop detectors mounted on or in spherical moderators. The results were collected in a large, searchable database and are intended to be used in the harmonisation of dosimetric procedures for mixed radiation fields and for the approval of dosimetry services in Europe.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncm169DOI Listing

Publication Analysis

Top Keywords

personal dosemeters
12
radiation fields
8
dosimetry techniques
8
nuclear industry
8
evaluation individual
4
dosimetry
4
individual dosimetry
4
dosimetry mixed
4
mixed neutron
4
neutron photon
4

Similar Publications

Development of equivalent dose assessment methodology for the lens of the eye at nuclear power plant workers.

Radiat Prot Dosimetry

December 2024

Korea Hydro & Nuclear Power Co., Ltd Central Research Institute (KHNP CRI), 70, Yuseong-daero 1312 Beon-gil, Yuseong-gu, Daejeon 34101, Republic of Korea.

As the International Commission on Radiological Protection lowers the equivalent dose limit for lens of the eye of radiation workers, the importance of radiation protection for the lens of the eye has been increased. In the case of poor working condition, such as high temperatures and humid environments at nuclear power plants, wearing an eye dosemeter near the worker's eye may interfere with work. In addition, it would not be reasonable for all workers to wear an eye dosemeter to evaluate the lens equivalent dose even in areas with an expected low exposure dose in the NPPs.

View Article and Find Full Text PDF

Systematic study on the influence of inductive chargers on active personal dosemeters.

J Radiol Prot

November 2024

Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.

Electromagnetic compatibility testing plays an important role in the type testing of radiation protection dosemeters in view of technical developments and the associated increase in electromagnetic fields. Lately, the use of inductive charging devices has grown as a user-friendly type of charging mobile-phones. In this article, we investigate their impact on active personal dosemeters (APD).

View Article and Find Full Text PDF

Aim: The aim of this study was to evaluate the occupational radiation exposure of staff during endoscopic retrograde cholangiopancreatography (ERCP), with a focus on individuals closest to the radiation source, and to identify potential increases in exposure to hands and eye lenses. Patient radiation exposure during ERCP was also assessed.

Materials And Methods: Staff organ doses were monitored using a Philips Allura Xper FD 20 fluoroscopy system, during 24 ERCP procedures for a period of 7 months.

View Article and Find Full Text PDF

The benefits of a cardiac resynchronization therapy (CRT) implantation are known in severe heart failure and its implantation may also be considered during pregnancy to ensure safe pregnancy and delivery for both the mother and the fetus. This study on a patient case aimed to estimate the absorbed dose (AD) to the fetus during the CRT implantation of 21st week of the pregnant woman. AD measurement was done using anthropomorphic phantom, radiophotoluminescence dosemeters and Monte Carlo simulation utilizing kerma area product (KAP) of the procedures.

View Article and Find Full Text PDF

Equivalent doses for the eye lenses, thyroid, and mammary glands were measured and compared between one adult and three pediatric anthropomorphic phantoms during chest computed tomography (CT) using 40 mm volume helical scan on the Aquilion ONE GENESIS Edition CT equipment. Placing an optically stimulated luminescence dosemeter (OSLD) on the eye lenses, thyroid, and mammary gland, we measured and compared the equivalent dose of OSLD among different phantoms during chest CT using a helical scan. Compared with adults, the equivalent doses to the eye lens, thyroid, and mammary glands were ~81%, 77%, and 63% lower in newborns, 1-year-olds, and 5-year-olds using comparable image noise during chest CT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!