Frame rate considerations for real-time abdominal acoustic radiation force impulse imaging.

Ultrason Imaging

Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.

Published: October 2006

With the advent of real-time Acoustic Radiation Force Impulse (ARFI) imaging, elevated frame rates are both desirable and relevant from a clinical perspective. However, fundamental limitations on frame rates are imposed by thermal safety concerns related to incident radiation force pulses. Abdominal ARFI imaging utilizes a curvilinear scanning geometry that results in markedly different tissue heating patterns than those previously studied for linear arrays or mechanically-translated concave transducers. Finite Element Method (FEM) models were used to simulate these tissue heating patterns and to analyze the impact of tissue heating on frame rates available for abdominal ARFI imaging. A perfusion model was implemented to account for cooling effects due to blood flow and frame rate limitations were evaluated in the presence of normal, reduced and negligible tissue perfusions. Conventional ARFI acquisition techniques were also compared to ARFI imaging with parallel receive tracking in terms of thermal efficiency. Additionally, thermocouple measurements of transducer face temperature increases were acquired to assess the frame rate limitations imposed by cumulative heating of the imaging array. Frame rates sufficient for many abdominal imaging applications were found to be safely achievable utilizing available ARFI imaging techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2254189PMC
http://dx.doi.org/10.1177/016173460602800401DOI Listing

Publication Analysis

Top Keywords

arfi imaging
20
frame rates
16
frame rate
12
radiation force
12
tissue heating
12
acoustic radiation
8
force impulse
8
imaging
8
abdominal arfi
8
heating patterns
8

Similar Publications

Background: At present, there is a dearth of objective methodologies for assessing the effectiveness of treatments for Lateral Epicondylitis (LE). This study examined 73 patients suffering from tennis elbow using a multimodal ultrasound approach and investigated the correlation between pertinent indicators and clinical scores.

Methods: 73 patients diagnosed with unilateral tennis elbow by interventional ultrasound at Zhejiang Rongjun Hospital were included in the study.

View Article and Find Full Text PDF

Objective: The objective of this study was to investigate the association between sarcopenia and liver fibrosis in patients aged 18-59 years with metabolic dysfunction-associated steatotic liver disease (MASLD) and to assess the potential of sarcopenia as a risk factor for the progression of liver fibrosis.

Methods: The study included 821 patients with MASLD in the US cohort and 3,405 patients with MASLD in the Chinese cohort. Liver controlled attenuation parameters (CAP) and liver stiffness measurements (LSM) were assessed by vibration-controlled transient elastography (VCTE) to evaluate the extent of hepatic steatosis and fibrosis.

View Article and Find Full Text PDF

Rett syndrome (RTT) is a neurodevelopmental disorder caused by mutations in the gene, potentially disrupting lipid metabolism and leading to dyslipidemia (DLD) and steatotic liver disease (SLD). Although SLD has been described in RTT mouse models, it remains undocumented in humans. We herein describe a 24-year-old woman with RTT who was evaluated for abnormal liver enzymes.

View Article and Find Full Text PDF

Myofascial pain is one of the common symptoms in patients with temporomandibular joint disorders (TMD). Occlusal splint (OS) and masticatory muscle trigger point (TP) local injections are primary treatment options. We aimed to investigate the effects of these treatments using clinical and elastography measures.

View Article and Find Full Text PDF

Objectives: To compare the values of ultrasound and clinical parameters for predicting outcomes of induction of labor (IOL) among healthy nulliparous women with a singleton, term cephalic pregnancy.

Methods: The cervical length, cervical strain elastography, posterior cervical angle, head-perineum distance, Bishop score, and maternal parameters were assessed before IOL with a combined method-Foley catheter and Misoprostol perorally. The main outcome was vaginal delivery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!