A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparative study of 2 methods for obtaining platelet-rich plasma. | LitMetric

A comparative study of 2 methods for obtaining platelet-rich plasma.

J Oral Maxillofac Surg

Department of Stomatology III, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain.

Published: June 2007

Purpose: Double and single centrifugation are the most commonly used techniques for obtaining platelet-rich plasma (PRP) in dentistry. In this study, we used and compared 2 methods for obtaining PRP: double centrifugation (ACE system; Surgical Supply and Surgical Science Systems, Brockton, MA) and single centrifugation (Nahita system; Nahita, Navarra, Spain).

Materials And Methods: Blood samples were obtained from 30 random patients. Each blood sample was treated using the ACE system and Nahita system methods, after which the obtained material was analyzed by flow cytometry for platelet counts and by transmission electron microscopy (TEM) for ultrastructural analysis of the PRP gel.

Results: Platelet count analysis of the PRP obtained from both methods revealed that the ACE and Nahita systems accomplished platelet concentrations of (336%) and (227%), respectively. The platelet counting results obtained from the ACE system samples were more dispersed than their Nahita system counterpart. The ultrastructural (ie, TEM) study showed considerable alterations of the platelet aggregates in the ACE's PRP, especially when the samples were not mixed in the final stage of the procedure, whereas the Nahita aggregates always had a normal physiological appearance.

Conclusions: The ACE double-centrifugation method is able to achieve higher platelet concentrations than the single-centrifugation Nahita system, although the results obtained by ACE were more dispersed. Nevertheless, the ACE system provoked alterations in the PRP ultrastructure, and it was more sensitive to small errors during preparation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joms.2006.09.012DOI Listing

Publication Analysis

Top Keywords

ace system
16
nahita system
16
methods obtaining
8
obtaining platelet-rich
8
platelet-rich plasma
8
single centrifugation
8
system
8
system nahita
8
analysis prp
8
platelet concentrations
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!