Anatomical predictions of hearing in the North Atlantic right whale.

Anat Rec (Hoboken)

Woods Hole Oceanographic Institution, Woods Hole, Massachusetts, USA.

Published: June 2007

Some knowledge of the hearing abilities of right whales is important for understanding their acoustic communication system and possible impacts of anthropogenic noise. Traditional behavioral or physiological techniques to test hearing are not feasible with right whales. Previous research on the hearing of marine mammals has shown that functional models are reliable estimators of hearing sensitivity in marine species. Fundamental to these models is a comprehensive analysis of inner ear anatomy. Morphometric analyses of 18 inner ears from 13 stranded North Atlantic right whales (Eubalaena glacialis) were used for development of a preliminary model of the frequency range of hearing. Computerized tomography was used to create two-dimensional (2D) and 3D images of the cochlea. Four ears were decalcified and sectioned for histologic measurements of the basilar membrane. Basilar membrane length averaged 55.7 mm (range, 50.5 mm-61.7 mm). The ganglion cell density/mm averaged 1,842 ganglion cells/mm. The thickness/width measurements of the basilar membrane from slides resulted in an estimated hearing range of 10 Hz-22 kHz based on established marine mammal models. Additional measurements from more specimens will be necessary to develop a more robust model of the right whale hearing range.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ar.20527DOI Listing

Publication Analysis

Top Keywords

basilar membrane
12
hearing
8
north atlantic
8
measurements basilar
8
hearing range
8
anatomical predictions
4
predictions hearing
4
hearing north
4
atlantic whale
4
whale knowledge
4

Similar Publications

Background: The pathological hallmark of Ménière's disease is endolymphatic hydrops, which can lead to an increase in basilar membrane stiffness and, consequently, an acceleration of the traveling wave of sound. The cochlear hydrops analysis masking procedure (CHAMP), which is an auditory brainstem response test masked at various frequencies with high-pass noise masking, uses the principle of the traveling wave velocity theory to determine the presence of endolymphatic hydrops.

Purpose: This study aimed to review the previous results of the CHAMP, expound the principles and key indicators, and discuss its clinical significance in diagnosing Ménière's disease.

View Article and Find Full Text PDF

Noise exposure is one of the most common causes of sensorineural hearing loss. Although many studies considered inflammation to be a major contributor to noise-induced hearing loss, the process of cochlear inflammation is still unclear. Studies have found that activation of the NF-κB signaling pathway results in the accumulation of macrophages in the inner ear plays an important role in hair cell damage.

View Article and Find Full Text PDF

Fluid-Structure Interaction Analysis of Trapezoidal and Arc-Shaped Membranes Mimicking the Organ of Corti.

Int J Numer Method Biomed Eng

January 2025

Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan.

In a previous study [H. Shintaku et al., Sensors and Actuators A: Physical 158 (2010): 183-192], an artificially developed auditory sensor device showed a frequency selectivity in the range from 6.

View Article and Find Full Text PDF

Exploring the impact of force direction and phase on bone conduction hearing with bone conduction actuator.

Hear Res

December 2024

Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291, Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; School of Mechanical & Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore. Electronic address:

A comprehensive understanding of the effects of bone conduction (BC) input force is essential for elucidating BC hearing mechanisms. However, this area remains underexplored due to the inherent difficulties in controlling input forces when BC transducers are anchored to the bone. In this study, the effects of both unilateral and bilateral BC input forces were investigated using a three-dimensional finite element (FE) model of the human head, which allows precise manipulation of input forces.

View Article and Find Full Text PDF

Mammalian hearing operates on three basic steps: 1) sound capturing, 2) impedance conversion, and 3) frequency analysis. While these canonical steps are vital for acoustic communication and survival in mammals, they are not unique to them. An equivalent mechanism has been described for katydids (Insecta), and it is unique to this group among invertebrates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!