Precision in stitches: Radius Surgical System.

Surg Endosc

Section for Minimally Invasive Surgery, Department of General, Visceral and Transplantation Surgery, University Hospital Tuebingen, Tuebingen, Germany.

Published: November 2007

Background: The Radius Surgical System is a manual manipulator with two additional degrees of freedom compared with conventional laparoscopic instruments (CLIs). This study aimed to compare the performance of laparoscopic suturing tasks with the use of the Radius Surgical System and CLIs, respectively.

Methods: Five experienced laparoscopic surgeons performed laparoscopic surgical tasks in a training box. The tasks consisted of knot-tying, suturing, and needle control tasks. The needle control task was performed to evaluate the precision of the needle drive by analysis of the needle exit point on a suture pad. In the knot-tying and suturing tasks, required time and accuracy value were measured. Needle control tasks were performed on three different angulations of plane. The angles between the instrument plane and the target plane (AIT) were 30 degrees, 60 degrees, and 90 degrees. The distance of the exit point to the center of the target field, the number of actions needed to fulfill a single task, and the required time were recorded and analyzed.

Results: In the knot-tying and frontal suturing tasks, there were no significant differences between the two groups. In the sagittal suturing task, the required time in the Radius group was significantly shorter than in the CLI group. In the needle control tasks on 30 degree and 60 degree AIT, the distance was significantly shorter in the Radius group than in the CLI group. There were no significant differences in the number of actions or the required time. In the frontal and sagittal needle control task on 90 degree AIT, the distance was significantly shorter in the Radius group than in the CLI group. The number of actions and the required time were significantly less in the Radius group than in the CLI group.

Conclusions: The two additional degrees of freedom contributed to accurate and controlled needle guidance, especially in difficult spatial situations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-007-9289-6DOI Listing

Publication Analysis

Top Keywords

needle control
20
required time
20
radius group
16
radius surgical
12
surgical system
12
suturing tasks
12
control tasks
12
number actions
12
cli group
12
group cli
12

Similar Publications

Objectives: Reporting the histological effects of chronic stress on certain oral tissues, as well as the capacity of Thymus vulgaris (thyme) to protect tissues from stress and link both serum cortisol and serotonin levels.

Methods: 30 rats were randomly divided into a trio of groups: normal control (no treatment), stress group (chronic stress without treatment), and treatment group (chronic stress treated with thyme at a dose of 200 mg/kg BW orally via needle gavage daily for 21 days). At the end of the experiment, tongues and major sublingual glands (SLGs) were surgically removed and processed for histological and histochemical studies.

View Article and Find Full Text PDF

The purpose of this study is to solve the problem of ammonia (NH) release when modified magnesium slag (MMS) is used as coal mine backfill cementitious material, and to explore its chemical mechanism and put forward effective solutions. Uniaxial compressive strengths (UCS) hydration kinetics, scanning electron microscope (SEM), and thermogravimetric analysis-derivative thermogravimetry (TG-DTG), X-ray diffractometer (XRD) and other testing methods were used to study the evolution of the properties of MMS-based backfill material, which provided a scientific basis for the safe utilization of MMS. First, the chemical mechanism underlying the release of NH from MMS was identified, and it was confirmed that MgN and LiN are the main nitrogen sources.

View Article and Find Full Text PDF

Protein aggregation, a major concern in biopharmaceutical quality control, can be accelerated by various stresses during clinical handling. This study investigated potential aggregation risk factors during dilution process with syringe handling for intravenous administration. Using γ-globulin and IgG solutions as surrogate models of antibody therapeutics, we examined the effects of high sliding speeds and piston operations of the syringe on protein aggregation during saline dilution.

View Article and Find Full Text PDF

Are ultrasonic tips associated with final irrigation protocols effective in removing biofilms in long oval canals and dentinal tubules?

Clin Oral Investig

January 2025

Department of Restorative Dentistry, Dental Materials, and Endodontics, Bauru School of Dentistry, University of São Paulo, Rua Siqueira Campos, 180, Centro, Vitória da Conquista, Bauru, São Paulo, BA, ZIP: 45.000-455, Brazil.

Objective: This study investigated the associations among endodontic instruments, ultrasonic tips and various final irrigation protocols for removing intracanal and intratubular biofilms in long oval canals.

Methodology: One hundred mandibular premolars inoculated with Enterococcus faecalis were divided into two groups: the control group (CG: n = 10), which received no treatment; and the test groups (n = 30), which included saline (SS), sodium hypochlorite (2.5% NaOCl) and chlorhexidine (2% CHX).

View Article and Find Full Text PDF

: It is unknown how early exercise therapy combined with acupuncture (AP) affects the speed of recovery in patients suffering from heart failure with reduced ejection fraction (HFrEF) who are hospitalized due to worsening HF. : A prospective, sham-procedure-controlled, double-blind, randomized clinical trial with three patient groups was conducted. The study included patients with HFrEF who were hospitalized for worsening HF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!