Colonic adenocarcinomas: near-infrared microcatheter imaging of smart probes for early detection--study in mice.

Radiology

Center for Molecular Imaging Research, Massachusetts General Hospital, Harvard Medical School, Bldg 149, 13th St, Room 5408, Charlestown, MA 02129, USA.

Published: July 2007

Purpose: To prospectively evaluate the ability of micro-fiberoptic catheters, which simultaneously record white light and near-infrared (NIR) images, to reveal colonic neoplasms after the intravenous administration of activatable "smart" probes that increase in NIR fluorescence subsequent to protease activation.

Materials And Methods: The institutional animal care committee approved all animal experiments. CT26 tumor cells were orthotopically implanted into the descending colon of C57BL6/J mice (n=10). Thirteen days later, mice intravenously received either 2 nmol of a protease-sensing probe that had cathepsin B as a major activator (n=5) or saline (control animals [n=5]). One day later, animals were noninvasively examined to the point of the splenic flexure by using microcatheter imaging. Excised colons were subsequently evaluated with epifluorescence imaging, histologic examination, and cathepsin B immunohistochemistry. Student t test was used for statistical analysis, with P<.05 considered to indicate a significant difference.

Results: Results with fiberoptic imaging demonstrated that all tumors were visible with the protease-activatable probe, even when they were not readily apparent at white light imaging. A target-to-background ratio (TBR) of 8.86 for tumor to adjacent normal mucosa was achieved in the NIR channel after probe administration (P=.001), whereas white light images resulted in a TBR of 1.14 (P>.5) based on luminosity. The tumoral NIR fluorescence intensity was more than 30-fold greater in probe-injected animals than in control animals, indicating that essentially all of the signal recorded in lesions was from activatable probe administration. Results of immunohistochemistry confirmed cathepsin B overexpression in the tumor compared with adjacent mucosa.

Conclusion: The use of NIR imaging microcatheters combined with protease-activatable smart probes results in a beacon effect that highlights tumors with high TBRs; this technique thus may be a potentially useful adjunct to white light colonoscopy in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2441052114DOI Listing

Publication Analysis

Top Keywords

microcatheter imaging
8
smart probes
8
white light
8
nir fluorescence
8
control animals
8
colonic adenocarcinomas
4
adenocarcinomas near-infrared
4
near-infrared microcatheter
4
imaging
4
imaging smart
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!