Analysis of dynamic angle of gait and radiographic features in subjects with hallux abducto valgus and hallux limitus.

J Am Podiatr Med Assoc

Centre for Musculoskeletal Studies, University of Western Australia, and Department of Surgery and Pathology, Royal Perth Hospital, Perth, Western Australia, Australia.

Published: September 2007

Background: Hallux abducto valgus and hallux limitus are two commonly encountered foot deformities causing altered structure and function of the first metatarsophalangeal joint and subsequent compensatory mechanisms. This study was undertaken to determine the relationships between these two deformities and transverse plane position of the foot, or angle of gait, and several radiographic angular and linear parameters with established reliability.

Methods: A convenience sample of 23 subjects with hallux abducto valgus, 22 subjects with hallux limitus, and 20 control subjects was used. Radiographic parameters were standardized weightbearing views and included lateral stressed dorsiflexion of the first metatarsophalangeal joint, composite, dorsoplantar, and lateral views. Angle of gait was obtained from powdered footprints recorded on paper. Two left and two right footprints identified on each trial were used to calculate angle of gait.

Results: The findings of the study suggest that an association between angle of gait and the presence of hallux abducto valgus or hallux limitus does not exist. Possible explanations may relate to the large variability of normal angle of gait, the need to identify factors extrinsic to the foot capable of affecting transverse plane orientation of the foot, and the addition of information relating to symptoms.

Conclusions: In this study, the presence of hallux abducto valgus or hallux limitus did not correspond to an association with a particular angle of gait. Length and elevation of the first metatarsal were associated in subjects with hallux abducto valgus and hallux limitus.

Download full-text PDF

Source
http://dx.doi.org/10.7547/0970175DOI Listing

Publication Analysis

Top Keywords

angle gait
24
hallux abducto
24
abducto valgus
24
hallux limitus
24
valgus hallux
20
subjects hallux
16
hallux
12
gait radiographic
8
metatarsophalangeal joint
8
transverse plane
8

Similar Publications

OpenCap, a smartphone-based markerless system, offers a cost-effective alternative to traditional marker-based systems for gait analysis. However, its kinematic measurement accuracy must be evaluated before widespread use in clinical practice. This study aimed to evaluate OpenCap for lower-limb joint angle measurements during walking in patients with knee osteoarthritis (OA) and to compare error metrics between patients and healthy controls.

View Article and Find Full Text PDF

Introduction: Gait analysis is a vital tool in the assessment of human movement and has been widely used in clinical settings to identify potential abnormalities in individuals. However, there is a lack of consensus on the normative values for gait metrics in large populations. The primary objective of this study is to establish a normative database of spatiotemporal gait metrics across various age groups, contributing to a broader understanding of human gait dynamics.

View Article and Find Full Text PDF

According to South Korea's Ministry of Employment and Labor, approximately 25,000 construction workers suffered from various injuries between 2015 and 2019. Additionally, about 500 fatalities occur annually, and multiple studies are being conducted to prevent these accidents and quickly identify their occurrence to secure the golden time for the injured. Recently, AI-based video analysis systems for detecting safety accidents have been introduced.

View Article and Find Full Text PDF

Clinical Whole-Body Gait Characterization Using a Single RGB-D Sensor.

Sensors (Basel)

January 2025

German Center for Vertigo and Balance Disorders (DSGZ), LMU University Hospital, LMU Munich, 81377 Munich, Germany.

Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy.

View Article and Find Full Text PDF

Preoperative muscle atrophy leads to persistent gait abnormalities in patients undergoing total hip arthroplasty (THA). Efficient motor learning of the gluteus medius is crucial for their recovery. In this study, a single-joint hybrid assistive limb (HAL) was developed to assist hip abduction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!