A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ambient oxygen concentrations resulting from use of the Lund University Cardiopulmonary Assist System (LUCAS) device during simulated cardiopulmonary resuscitation. | LitMetric

Introduction: Supplementary oxygen is used routinely during cardiopulmonary resuscitation (CPR). High ambient oxygen levels from ventilation circuits have caused fatal fires and explosions. The Lund University Cardiopulmonary Assist System (LUCAS) device is driven by > 70 l min(-1) oxygen which is also likely to increase ambient oxygen concentrations and cause similar risk of fire and explosion. This study used simulated CPR with a LUCAS device to measure resulting ambient oxygen concentrations and assess safety of the device.

Material And Methods: Simulated manikin CPR using a LUCAS device was performed outdoors, inside an ambulance (ventilation off and ventilation on full power), and in a resuscitation bay. Ambient oxygen concentrations were measured over the apical and sternal defibrillation sites and midway between the two, at the head and 1m horizontally above the head. Recordings were made for 5 min when the LUCAS device was turned on and for a further 5 min when turned off.

Results: Ambient oxygen concentration increased quickly in all four scenarios. Peak oxygen levels over the chest were highest in the resuscitation bay (36.7%) and lowest in the ambulance with ventilation on full power (33.8%). Oxygen levels decreased to baseline within 5 min of turning off the LUCAS device.

Conclusion: The use of oxygen to drive the LUCAS device results in a rapid increase in ambient oxygen concentration to levels likely to risk injury or death from fire. Ambulance services and hospitals using the device must be alerted to these dangers immediately.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resuscitation.2007.04.001DOI Listing

Publication Analysis

Top Keywords

ambient oxygen
28
lucas device
24
oxygen concentrations
16
oxygen levels
12
oxygen
11
lund university
8
university cardiopulmonary
8
cardiopulmonary assist
8
assist system
8
system lucas
8