Unlabelled: Multimodality PET/CT of the liver can be performed with an integrated (hybrid) PET/CT scanner or with software fusion of dedicated PET and CT. Accurate anatomic correlation and good image quality of both modalities are important prerequisites, regardless of the applied method. Registration accuracy is influenced by breathing motion differences on PET and CT, which may also have impact on (attenuation correction-related) artifacts, especially in the upper abdomen. The impact of these issues was evaluated for both hybrid PET/CT and software fusion, focused on imaging of the liver.
Methods: Thirty patients underwent hybrid PET/CT, 20 with CT during expiration breath-hold (EB) and 10 with CT during free breathing (FB). Ten additional patients underwent software fusion of dedicated PET and dedicated expiration breath-hold CT (SF). The image registration accuracy was evaluated at the location of liver borders on CT and uncorrected PET images and at the location of liver lesions. Attenuation-correction artifacts were evaluated by comparison of liver borders on uncorrected and attenuation-corrected PET images. CT images were evaluated for the presence of breathing artifacts.
Results: In EB, 40% of patients had an absolute registration error of the diaphragm in the craniocaudal direction of >1 cm (range, -16 to 44 mm), and 45% of lesions were mispositioned >1 cm. In 50% of cases, attenuation-correction artifacts caused a deformation of the liver dome on PET of >1 cm. Poor compliance to breath-hold instructions caused CT artifacts in 55% of cases. In FB, 30% had registration errors of >1 cm (range, -4 to 16 mm) and PET artifacts were less extensive, but all CT images had breathing artifacts. As SF allows independent alignment of PET and CT, no registration errors or artifacts of >1 cm of the diaphragm occurred.
Conclusion: Hybrid PET/CT of the liver may have significant registration errors and artifacts related to breathing motion. The extent of these issues depends on the selected breathing protocol and the speed of the CT scanner. No protocol or scanner can guarantee perfect image fusion. On the basis of these findings, recommendations were formulated with regard to scanner requirements, breathing protocols, and reporting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2967/jnumed.107.041517 | DOI Listing |
Background: Adaptive radiotherapy (ART) involves the continuous adaptation of the radiation plan according to patient- and tumor-specific feedback. In online ART, the plan is optimized in real time during the treatment; in offline ART, the plan is recalculated between treatment sessions. Hybrid linear accelerators with integrated CT, MRI, or PET are required to perform online ART.
View Article and Find Full Text PDFDiagnostics (Basel)
November 2024
Faculty of Medicine, Department of Medical Imaging and Nuclear Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, 8 V. Babeș St., 400006 Cluj-Napoca, Romania.
Background: Struma ovarii is a rare tumor, a type of ovarian mature teratoma consisting over 50% of its mass in thyroid ectopic tissue; 5% to 10% of cases, as described in the literature, are malignant and well known as malignant struma ovarii or thyroid cancer from struma ovarii. Due to the limited number of malignant struma ovarii cases, the diagnostic and therapeutic approach of malignant struma ovarii lacks in standardization.
Methods: We performed a comprehensive search on the English language PubMed and Google Scholar.
Zh Vopr Neirokhir Im N N Burdenko
December 2024
Polenov Neurosurgical Institute, St-Petersburg, Russia.
Unlabelled: Primary central nervous system vasculitis is still a challenge due to rarity of disease, unspecific clinical and neurological presentation, as well as low specificity of MRI and laboratory tests.
Objective: To present the potential of hybrid neuroimaging in diagnosis of primary central nervous system vasculitis.
Material And Methods: The results of MRI, PET/CT with 11C-methionine, histological and immunochemical data in a 23-year-old patient with first-time epileptic seizure are demonstrated.
Front Oncol
November 2024
Department of Nuclear Medicine, University Hospital Basel, Basel, Switzerland.
Purpose: To optimize and assess an abbreviated dual time-point 18-Fluor-Deoxyglucose (FDG)-Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) protocol for predicting patient outcomes in pancreatic cancer.
Methods: 70 patients (47 pancreatic cancer, 23 chronic pancreatitis) underwent hybrid PET/MRI with dual time-point PET/CT at 60 and 84 minutes post-injection. Metabolic indices (MI) were calculated from Standardized Uptake Value (SUV) changes (SUVmin, SUVmean and SUVmax).
J Neuroendocrinol
December 2024
Nuclear Medicine, Alma Mater Studiorum University of Bologna, Bologna, Italy.
Assessing the response to systemic therapy in neuroendocrine tumors (NET) is challenging since morphological imaging response is often delayed and not necessarily reflective of clinical benefit. Peptide receptor radionuclide therapy (PRRT) has a complex mechanism of action, further complicating response assessment. In response to these challenges, the European Neuroendocrine Tumor Society (ENETS) Theranostics Task Force conducted a statement-based survey among experts to identify the current landscape and unmet needs in PRRT response assessment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!