A pulsed electron gun for ultrafast electron diffraction at surfaces.

Rev Sci Instrum

Department of Physics and Centre for Nanointegration CeNIDE, University of Duisburg-Essen, 47048 Duisburg, Germany.

Published: January 2007

The construction of a pulsed electron gun for ultrafast reflection high-energy electron diffraction experiments at surfaces is reported. Special emphasis is placed on the characterization of the electron source: a photocathode, consisting of a 10 nm thin Au film deposited onto a sapphire substrate. Electron pulses are generated by the illumination of the film with ultraviolet laser pulses of femtosecond duration. The photoelectrons are emitted homogeneously across the photocathode with an energy distribution of 0.1 eV width. After leaving the Au film, the electrons are accelerated to kinetic energies of up to 15 keV. Focusing is accomplished by an electrostatic lens. The temporal resolution of the experiment is determined by the probing time of the electrons traveling across the surface which is about 30 ps. However, the duration of the electron pulses can be reduced to less than 6 ps.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.2431088DOI Listing

Publication Analysis

Top Keywords

pulsed electron
8
electron gun
8
gun ultrafast
8
electron diffraction
8
electron pulses
8
electron
6
ultrafast electron
4
diffraction surfaces
4
surfaces construction
4
construction pulsed
4

Similar Publications

Novel coumarin-triphenyliminophosphorane (TPIPP) fluorophores, synthesized via a nonhydrolytic Staudinger reaction, exhibit remarkable redox-responsive optical properties. Upon chemical and electrochemical oxidation, these compounds display a hypsochromic shift in absorption from 430 to 350 nm, accompanied by up to 11-fold fluorescence enhancement under 405 nm excitation. The fluorescence switching occurs at an electrochemical oxidation potential of approximately +2.

View Article and Find Full Text PDF

The inclusion of redox mediators into electrocatalytic systems facilitates rapid electron shuttling kinetics and boosts the overall catalytic performance of the electrode. This approach overcomes the sluggish reaction dynamics associated with direct electron transfer, which may be impeded by restricted analyte access to the electrode's active sites. In contrast to conventional synthetic redox mediators, naturally sourced phytomolecule rutin trihydrate (RT), extracted from apple juice, offers potential ecological advantages.

View Article and Find Full Text PDF

To what extent sildenafil, a selective inhibitor of the type-5 phosphodiesterase modulates systemic redox status and cerebrovascular function during acute exposure to hypoxia remains unknown. To address this, 12 healthy males (aged 24 ± 3 y) participated in a randomized, placebo-controlled crossover study involving exposure to both normoxia and acute (60 min) hypoxia (Fi = 0.14), followed by oral administration of 50 mg sildenafil and placebo (double-blinded).

View Article and Find Full Text PDF

This paper summarizes the main findings of a study which aimed to examine the electrochemical oxidation of homovanillic acid (HVA), the final metabolite of dopamine. A pencil graphite electrode (PGE) was used as working electrode and the measurements were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The type and the composition of the graphite leads used as PGE, the pH of the supporting electrolyte, as well as the scan rates were optimized by CV.

View Article and Find Full Text PDF

Preparation of CHS-FeO@@ZIF-8 peroxidase-mimic with an ultra-thin hollow layer for ultrasensitive electrochemical detection of kanamycin.

Mikrochim Acta

January 2025

Key Laboratory for Palygorskite Science and Applied Technology of Jiangsu Province, National & Local Joint Engineering Research Center for Mineral Salt Deep Utilization, Huaiyin Institute of Technology, Huaian, 223003, P. R. China.

A highly sensitive and selective electrochemical biosensor was developed for the detection of kanamycin using a core-hollow-shell structured peroxidase-mimic nanozyme, CHS-Fe₃O₄@@ZIF-8. The synthesized CHS-FeO@@ZIF-8 was characterized with scanning electron microscopy, transmission electron microscopy, and X-ray photoelectron spectroscopy. It was found that the CHS-FeO@@ZIF-8 exhibits excellent peroxidase-like activity due to  its ultra-thin hollow layer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!