Background: It has been considered that implant prostheses ought to display passive fit. The objective of this finite element analysis (FEA) was to simulate the bone loading resulting from the fixation of implant-supported three and five-unit fixed partial dentures (FPDs).
Methods: Based on a patient case, six different FPD-groups were fabricated using either two or three implants for support. Strain gauges on the pontics of the prostheses were used for in vivo measurements. Based on the values obtained, bone loading models were simulated using three-dimensional finite element analysis and the results obtained were represented as von Mises equivalent stress.
Results: The mean strain (epsilon) values ranged from 15 micro epsilon to 170 micro epsilon for the three-unit FPDs and from 32 micro epsilon to 302 micro epsilon for the five-unit FPDs. FEA revealed von Mises stresses up to 30 MPa in the cortical area, while in trabecular bone values up to 5 MPa were observed. Static implant loading of similar magnitude can be provoked through 200 N axial load.
Conclusions: Although the in vivo measured strain levels (epsilon) were of higher magnitude for the five-unit prostheses, FEA revealed bone loading of comparable magnitude for both three- and five-unit FPDs. Multi-unit prostheses may demonstrate greater inaccuracies compared with single implant restorations, but due to the absence of moment loading the multi-implant configuration appears to compensate for the higher strain development.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1834-7819.2007.tb00465.x | DOI Listing |
J Exp Orthop
January 2025
Department of Orthopedic Surgery and Traumatology, Freiburg University Hospital Albert Ludwigs University Freiburg Freiburg Germany.
Introduction: The medial patellofemoral ligament (MPFL) is the main patellar stabilizer in low knee flexion degrees (0-30°). Isolated MPFL reconstruction (MPFLr) is therefore considered the gold standard of surgical procedures for low flexion patellofemoral instabilities (PFIs). Despite excellent clinical results, little is known about the effect of MPFLr on kinematic parameters (KPs) of the patellofemoral joint in vivo.
View Article and Find Full Text PDFFront Bioeng Biotechnol
December 2024
Department of Orthopedics, The First Affiliated Hospital of Soochow University, Soochow University, Suzhou, Jiangsu, China.
In mammalian species, neural tissues cannot regenerate following severe spinal cord injury (SCI), for which stem cell transplantation is a promising treatment. Neural stem cells (NSCs) have the potential to repair SCI; however, in unfavourable microenvironments, transplanted NSCs mainly differentiate into astrocytes rather than neurons. In contrast, bone mesenchymal stem cells (BMSCs) promote the differentiation of NSCs into neurons and regulate inflammatory responses.
View Article and Find Full Text PDFOpen Vet J
November 2024
Orthopedics Unit, "Dr. Victor Popescu" Emergency Military Hospital, Timisoara, România.
Background: Cancellous bone mechanical properties are directly linked to structural integrity, which is a result of bone quantity, the quality of its bone matrix, and its microarchitecture. Several studies highlighted the bone behavior under specific loads, contributing to understanding risk factors and developing more effective therapeutic strategies. The anatomy and stability of iliac bone fractures, providing insight into pelvic trauma management.
View Article and Find Full Text PDFBMC Oral Health
December 2024
Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand.
Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.
Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.
Front Biosci (Elite Ed)
October 2024
Department of Medical Biotechnology, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, 1983969411 Tehran, Iran.
Background: Regenerative endodontics requires an innovative delivery system to release antibiotics/growth factors in a sequential trend. This study focuses on developing/characterizing a thermoresponsive core-shell hydrogel designed for targeted drug delivery in endodontics.
Methods: The core-shell chitosan-alginate microparticles were prepared by electrospraying to deliver bone morphogenic protein-2 for 14 days and transforming growth factor-beta 1 (TGF-β1) for 7-14 days.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!