A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Balloon-based in vitro MDI aerosol deposition experiments on the effects of mouthpiece diameter. | LitMetric

For this article, we studied the effects of mouthpiece diameter and flow rate on aerosol penetration efficiency for metered-dose inhaler (MDI) applications. Measurements show that increasing the mouthpiece diameter has a moderate and positive influence on the particle penetration efficiency of the MDI. The particle penetration efficiency increases monotonically with the increase of the mouthpiece diameter from 16 mm to 20 mm. Second, the experiments show that airflow rate has an apparent and significant effect on particles deposition in the oral airway. The reduction of the airflow rate from 90 L/min to 30 L/min tripled the penetration efficiency of the MDI. A new experimental system has been employed to measure the particles deposition in the human airways. Expansion balloons were used to induce airflow as well as to collect the penetrated particles through an airway cast. The potential advantages of the balloon-based experimental system are simplicity, accuracy, and cost-effectiveness.

Download full-text PDF

Source
http://dx.doi.org/10.1080/08958370701271688DOI Listing

Publication Analysis

Top Keywords

mouthpiece diameter
16
penetration efficiency
16
effects mouthpiece
8
particle penetration
8
efficiency mdi
8
airflow rate
8
particles deposition
8
experimental system
8
balloon-based vitro
4
mdi
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!