A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The use of polyacrylamide gel in soft-tissue augmentation: an experimental assessment. | LitMetric

Background: An increasing number of soft-tissue filler substances that lack experimental and clinical data have been introduced into plastic surgery practice outside the United States. One of these substances is polyacrylamide gel. It contains 2.5% polyacrylamide and 97.5% water. It is homogenous and stable, and has optimum viscosity and elasticity.

Methods: One milliliter of polyacrylamide gel was injected into the subcutaneous layer of the right ear in 28 rabbits. The rabbits were divided into two groups, according to when the material was harvested and evaluated. Material was harvested at 4 months in 15 rabbits and 7 months in 13 rabbits. Each group underwent volumetric ultrasound evaluation, magnetic resonance imaging, and histological evaluation with hematoxylin and eosin and CD68 staining.

Results: Results were easily observed because of the superficial position of the injected material. There were no systemic or local complications. The samples harvested showed a clear and jelly-like consistency similar to that of the initially injected material. The volume was constant after 6 weeks, after an initial period of acute stretching. Ultrasound volumetric analysis was also constant in all groups. At 7 months, a stable volume of 1.0 +/- 0.2 ml was observed. Magnetic resonance imaging scanning showed that the material was stable and that there was no inflammatory reaction. Histological analysis revealed a minimal foreign-body reaction, and the injected material was occasionally surrounded by a thin collagen membrane. The material remained in place.

Conclusions: Polyacrylamide gel has a long-lasting effect, with minimal volume variation. It remains soft to the touch and in place.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.prs.0000254824.13065.3bDOI Listing

Publication Analysis

Top Keywords

polyacrylamide gel
16
injected material
12
material harvested
8
months rabbits
8
magnetic resonance
8
resonance imaging
8
material
7
polyacrylamide
5
gel soft-tissue
4
soft-tissue augmentation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!