Objective: We report a clinical observation showing that continuous exposure to heparin via a central venous catheter is associated with patent ductus arteriosus treatment failure with indomethacin in very low birthweight infants.

Study Selection: A clinical observational case report in infants weighting <1501 g.

Data Extraction: This study compares the rates of patent ductus arteriosus treatment failure during a) the index period from June 2, 2003, to August 22, 2003, when all very low birthweight infants with a peripherally inserted central venous catheter received continuous infusion of heparinized parenteral nutrition; b) the baseline period of 1 yr before the index period; and c) the postindex period of 1 yr after the index period.

Data Synthesis: The rate of patent ductus arteriosus treatment failure with indomethacin increased significantly during the index period compared with the baseline (odds ratio, 7.0; 95% confidence interval, 1.41-34.7; p = .017) and postindex periods (odds ratio, 33.8; 95% confidence interval, 4.72-243; p = .0005). The result was confirmed in logistic multivariable regression analysis.

Conclusion: This observation, based on a case series and their controls, serves as a basis for a new hypothesis suggesting that continuous exposure to heparin through heparinized central venous infusion significantly increases patent ductus arteriosus treatment failure with indomethacin. This hypothesis needs to be tested in a randomized controlled trial.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.pcc.0000270203.07648.8eDOI Listing

Publication Analysis

Top Keywords

ductus arteriosus
8
low birthweight
8
preliminary report--heparin
4
report--heparin counteracts
4
counteracts indomethacin
4
indomethacin ductus
4
arteriosus low
4
birthweight infants
4
infants objective
4
objective report
4

Similar Publications

Background: Randomized controlled trials (RCTs) have failed to demonstrate the beneficial effects of the pharmacological treatment of patent ductus arteriosus (PDA) in preterm infants. We conducted a Bayesian model averaged (BMA) meta-analysis of RCTs comparing the pharmacological treatment of PDA with placebo or expectant treatment.

Methods: We searched for RCTs including infants with gestational age (GA) ≤ 32 weeks and with a rate of open-label treatment of less than 25% in the control arm.

View Article and Find Full Text PDF

Conjoined twin patients with patent ductus arteriosus and hemodynamic repercussions have a worse prognosis. In the present case report, we demonstrate the first successful percutaneous closure of the ductus arteriosus with the Piccolo© device (Abbot Structural Heart, Plymouth, MN, USA) in this type of clinical situation.

View Article and Find Full Text PDF

Patent Ductus Arteriosus Morphology Changes in Preterm Neonates Undergoing Transcatheter Device Closure.

Pediatr Cardiol

January 2025

Division of Cardiology, Children's Healthcare of Atlanta, Emory University School of Medicine, 2970 Brandywine Rd, Suite 125, Atlanta, GA, 30341, USA.

Evaluate patent ductus arteriosus (PDA) morphology changes in the preterm neonate undergoing transcatheter PDA closure (TCPC). We propose the type F ductus is associated with lower corrected gestational age (CGA) and improved TCPC outcomes. Retrospective review of premature neonates undergoing TCPC at a large volume institution from November 2020 to November 2023.

View Article and Find Full Text PDF

Off-pump Laks-type central shunt for tricuspid atresia with small branch pulmonary arteries.

Multimed Man Cardiothorac Surg

January 2025

• Department of Cardiac Sciences, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Jeddah, Saudi Arabia • King Abdullah International Medical Research Center, Ministry of National Guard Health Affairs, Jeddah, Saudi Arabia • College of Medicine, King Saud bin Abdulaziz University for Health Sciences, Ministry of National Guard Health Affairs, Jeddah, Saudi Arabia.

Prostaglandin E1 is a potent vasodilator that prevents the ductus arteriosus from closing. Its use in neonates with cyanotic heart defects has revolutionized the management of children with cyanotic heart defects. Although the use of prostaglandin E1 is a temporary solution, the establishment of dependable pulmonary blood flow is of paramount importance.

View Article and Find Full Text PDF

Pulmonary atresia with ventricular septal defect (PA-VSD) is usually diagnosed by transthoracic or fetal echocardiography, with the prenatal diagnosis being feasible and accurate if fetal cardiology services are available. The limitations of transthoracic echocardiography (TTE) in the evaluation of PA-VSD include the complete evaluation of the pulmonary arteries and patent ductus arteriosus, quantitative evaluation of the right ventricle size and function, and delineation of associated cardiac anomalies such as coronary artery anomalies, anomalies of systemic or pulmonary venous return, and complex arch anomalies. Echocardiography also has limitations in evaluating hemodynamics such as flow volumes, shunts, and regurgitant fraction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!