Study Design: This article describes a computer model of the cadaver cervical spine specimen and virtual biomechanical testing.
Objectives: To develop a graphics-oriented, multibody model of a cadaver cervical spine and to build a virtual laboratory simulator for the biomechanical testing using physics-based dynamic simulation techniques.
Summary Of Background Data: Physics-based computer simulations apply the laws of physics to solid bodies with defined material properties. This technique can be used to create a virtual simulator for the biomechanical testing of a human cadaver spine. An accurate virtual model and simulation would complement tissue-based in vitro studies by providing a consistent test bed with minimal variability and by reducing cost.
Method: The geometry of cervical vertebrae was created from computed tomography images. Joints linking adjacent vertebrae were modeled as a triple-joint complex, comprised of intervertebral disc joints in the anterior region, 2 facet joints in the posterior region, and the surrounding ligament structure. A virtual laboratory simulation of an in vitro testing protocol was performed to evaluate the model responses during flexion, extension, and lateral bending.
Results: For kinematic evaluation, the rotation of motion segment unit, coupling behaviors, and 3-dimensional helical axes of motion were analyzed. The simulation results were in correlation with the findings of in vitro tests and published data. For kinetic evaluation, the forces of the intervertebral discs and facet joints of each segment were determined and visually animated.
Conclusions: This methodology produced a realistic visualization of in vitro experiment, and allowed for the analyses of the kinematics and kinetics of the cadaver cervical spine. With graphical illustrations and animation features, this modeling technique has provided vivid and intuitive information.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.brs.0000263331.78903.61 | DOI Listing |
BMC Med Res Methodol
January 2025
Medical Spinal Research Unit, Spine Centre of Southern Denmark, University Hospital of Southern Denmark, Kolding, Denmark.
Background: Spinal pain affects up to 30% of school-age children and can interfere with various aspects of daily life, such as school attendance, physical function, and social life. Current assessment tools often rely on parental reporting which limits our understanding of how each child is affected by their pain. This study aimed to address this gap by developing MySpineData-Kids ("MiRD-Kids"), a tailored patient-reported questionnaire focusing on children with spinal pain in secondary care (Danish hospital setting).
View Article and Find Full Text PDFScand J Med Sci Sports
January 2025
Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark.
Reliable and sensitive testing of physical function is crucial for assessing the effects of treatment or exercise intervention in various patient populations. The present study investigated the test-retest reliability and sensitivity (smallest detectable difference: SDD) of selected physical performance tests commonly used in clinical rehabilitation, including tests of habitual and maximal walking speed, walking endurance capacity, handgrip strength (HGS), and lower limb muscle power (Sit-to-Stand (STS), stair climb) in adults with severe obesity meeting the criteria for bariatric surgery. Thirty-two adults (BMI 43.
View Article and Find Full Text PDFScand J Med Sci Sports
January 2025
Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark.
Physical activity (PA) reduces the risk of negative mental and physical health outcomes in older adults. Traditionally, PA intensity is classified using METs, with 1 MET equal to 3.5 mL O·min·kg.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).
View Article and Find Full Text PDFSci Data
January 2025
Department of Anatomy and Anthropology, Faculty of Medical & Health Sciences, Tel- Aviv University, Tel-Aviv, 699780, Israel.
This data descriptor presents a comprehensive and replicable dataset and method for calculating the cervical range of motion (CROM) utilizing quaternion-based orientation analysis from Delsys inertial measurement unit (IMU) sensors. This study was conducted with 14 participants and analyzed 504 cervical movements in the Sagittal, Frontal and Horizontal planes. Validated against a Universal Goniometer and tested for reliability and reproducibility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!