Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We report on galvanostatically controlled solid-state reversible ion-selective sensors for cationic analytes utilizing a conducting polymer as a transduction layer between the polymeric membrane and electron-conductive substrate. The instrumental control of polymeric membrane ion-selective electrodes based on electrochemically induced periodic ion extraction in alternating galvanostatic/potentiostatic mode was introduced recently creating exciting possibilities to detect clinically relevant polyions such as heparin and protamine and drastically improve the sensitivity of ion-selective sensors limited by the Nernst equation. The present study forms the basis for development of reliable, robust, and possibly maintenance-free sensors that can be fabricated using screen-printing technology. Various aspects of the development of solid-contact galvanostatically controlled ion-selective electrodes with a conducting polymer as a transduction layer are considered in the present work on the example of a model system based on a sodium-selective membrane. The protamine-selective solid-contact sensor was fabricated and characterized, which represents the next step toward commercially viable polyion sensing technology. A substantial improvement of a low detection limit (0.03 mg L-1) was achieved. A simplified diffusion-based theoretical model is discussed predicting the polarization at the interface of the conducting polymer and the membrane, which can cause the disruption of the sensor response function at relatively small current densities.