This study is a contribution to the growing body of work on the influence of changes in the composition of an acrylic bone cement on various properties of the curing and cured material. The focus is on one commercially-available acrylic bone cement brand, Surgical Simplex P, and three variants of it and a series of properties, namely, setting time, maximum exotherm temperature, activation energy and frequency factor for the polymerization reaction, diffusion coefficient for the uptake of phosphate buffered saline, at 37 degrees C, ultimate compressive strength (UCS), plane-strain fracture toughness, fatigue life (under fully-reversed tension-compression stress), hardness (H) and elastic modulus (both determined using quasi-static nanoindentation), and the variation of the storage and loss moduli with frequency of the applied force in a dynamic nanoindentation test. It was found that (a) a 68% reduction in the volume of the activator, N,N dimethyl-4-toluidine, relative to the total volume of the liquid monomer (the amounts of all the constituents in the powder and of the hydroquinone in the liquid monomer remaining unchanged) led to, for example, a significant decrease in the rate of the polymerization reaction, at 37 degrees C (c') and a significant increase in H; and (b) the elimination of the pre-polymerized poly (methyl methacrylate) beads in the powder (the amounts of all the other powder constituents and those of the liquid monomer remaining unchanged) led to, for example, a significant drop in c' and a significant increase in UCS. Thus, these findings suggest a strategy for optimizing the composition of an acrylic bone cement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10856-007-3042-5 | DOI Listing |
Expert Rev Med Devices
January 2025
Department of Orthopaedic Surgery, Kansai Medical University, Hirakata, Osaka, Japan.
Introduction: There is a worldwide trend toward 'revisiting' cemented total hip arthroplasty (THA). In Japan, however, cemented THAs accounts for 11%, and the percentage of cemented hemiarthroplasty is estimated to be less than 10%. This review was designed to reconsider the option of cemented THA and to encourage policy changes in Japan to support the best possible care for patients.
View Article and Find Full Text PDFBMC Oral Health
December 2024
Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand.
Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.
Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.
Sci Rep
December 2024
Student Research Committee, Department of Epidemiology, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Very high heat is generated during the polymerization of poly (methyl methacrylate) (PMMA) bone cement, which is used for implant fixation in orthopedic surgery. As such, it has been suggested that irrigating the bone cement layer in the surgical site with a saline solution is a way of cooling the layer. In this study, we aimed to determine the influence of irrigation with a saline solution on the flexural strength and the microstructure of the test specimens of two PMMA bone cement brands: Simplex P and FIX 1.
View Article and Find Full Text PDFMed Oral Patol Oral Cir Bucal
January 2025
C/Feixa Llarga s/n L´Hospitalet de Llobregat, 08927 Barcelona, Spain
Background: Although there are many works analyzing the clinical behavior of immediate loading of implants inserted by guided surgery, the literature referring specifically to elderly patients is scarce. The aim of this investigation is to present the clinical outcomes of immediate loading of implants inserted by guided surgery in geriatric patients with edentulous maxilla.
Material And Methods: The clinical data of 20 elderly patients with edentulous jaws are analyzed retrospectively.
Ann Ital Chir
December 2024
Department of Cardiovascular Surgery, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy; Department of Biomedical, Surgical, and Dental Sciences, University of Milan, 20122 Milan, Italy.
Aim: Percutaneous vertebroplasty is generally considered a safe procedure, however, cases of cardioembolism and cardiac perforation have been reported.
Case Presentation: A 69-year-old woman was referred to our emergency department after an outpatient echocardiogram revealed a "thrombus-like" formation involving the right heart. Two weeks before she had undergone percutaneous vertebroplasty of the third to fifth lumbar vertebrae due to osteoporotic fractures.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!